Call Now Book Service Online Estimate Specials

Brayan

Brayan

Service Technician

Rating

Reviews

Since joining Hydes in 2022, Brayan has quickly established himself as a trusted technician known for professionalism and reliability. He is NATE certified, the highest standard in the HVAC industry, and also holds an HVAC certificate from College of the Desert. Customers often highlight his courteous approach, clear communication, and patience in walking them through their equipment. Outside of work, Brayan enjoys attending sporting events and cheering for the Dodgers, Lakers, and Rams.

Name: Brayan

Certifications: NATE

Recent Jobs and Reviews

Rated 5.0 out of 5 stars based on 1269 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation for the service provided. Customers consistently express gratitude and praise for the professionalism, knowledge, and courtesy demonstrated by the technicians. Recurring themes include exceptional customer service, with technicians being described as friendly, respectful, polite, and professional throughout their interactions. Technical expertise is another dominant positive trend, as customers frequently commend the thorough diagnostics, efficient problem-solving, and clear explanations provided during service calls. Many reviewers highlight the promptness and reliability of the service, noting quick response times, punctuality, and efficient completion of work. The dedication to resolving complex or frustrating situations is particularly appreciated, with several customers expressing relief and happiness at having their HVAC and electrical issues successfully addressed. There is also notable appreciation for the transparency and honesty in service delivery, with customers valuing straightforward communication without unnecessary upselling. Long-term customer loyalty emerges as a theme, with multiple reviewers mentioning years of positive experiences and enthusiastic recommendations to neighbors and friends. The overall tone is one of trust, satisfaction, and genuine appreciation for quality workmanship and customer-focused service.

At a glance

Hydes Air Conditioning has completed 25 jobs in October 2026.

The 15 customer reviews shown here average 5.0 out of 5.

The most recent job was on October 13, 2026.

Recent work covers Palm Desert, CA, Palm Springs, CA, Rancho Mirage, CA, Indio, CA and Indian Wells, CA.

Reviews

Very courteous and knowledgeable
came in as express helper d was very courteous
Vera - Palm Desert, CA 92211
Excellent service
Very knowledgeable, well trained, and courteous
James - Palm Springs, CA 92262
Excellent fall check-up!
Brayan was on time, professional and took time explaining what he serviced and answered all my questions. I have used Hyde’s for years and their consistent quality service is very much appreciated.
Ray - Palm Springs, CA 92264
Excellent as it always is
Jay - Palm Springs, CA 92264
Wonderful service call
Brayan showed up on time. He was very organized. He told me exactly what he was going to do. He changed the (3) filters, inspected the outside units, & tested all (4) thermostats.
Melinda - Indian Wells, CA 92210
Professional service
Brayan the well trained and courteous tech arrived on time and explained what he was there to do. We find the seasonal service and inspections provides great peace of mind. Hyde’s never try to upsell and are very professional in their approach. We’ve spent a lot of money on new HVAC systems and have been pleased with their performance. Highly recommend.
Patrick - Rancho Mirage, CA 92270
Professional!
Teresa - Palm Desert, CA 92211
I’m grateful that we bought a twice yearly service for our air conditioners. We have almost always had very good service from Hyde’s and their very g
We have always had good service and appreciate the office staff as well as those technicians who come out to the house. Lots of times the girls in the office are also very helpful with questions and their communication as to appointments, etc.
Marta - Rancho Mirage, CA 92270
Great!
Very efficient. Good communication.
Kathy - Palm Springs, CA 92262
Great service
Fast, efficient and cordial
Julian - Palm Desert, CA 92211
Hyde’s makes it so easy!
Shawn - Palm Desert, CA 92260
Hydes always does a great job!
Maria - Indio, CA 92201
Excellent
Not happy about leak … but that has nothing to do with Bryan’s services. Bryan was upfront about leaks and work needed to be done.
Jean - Indio, CA 92203
Excellent service
Brayan was courteous and efficient.
Edith - Indio, CA 92201
Excellent service
Polite, efficient; answered all questions
Karen - Indio, CA 92203

Job Locations

Brayan T.
Brayan T.
Upon arrival unit was idle with temperature satisfied. Tested and cycled. Compressor and fan motor amps are in range. Measured proper communicating 12.5 VDC. Multiple error codes for air cleaner but none are installed. Need to return to replace 1050 thermostat. Notified office to schedule return to swap thermostat.
Palm Desert, CA 92211
Palm Desert, CA - Upon arrival unit was idle with temperature satisfied. Tested and cycled. Compressor and fan motor amps are in range. Measured proper communicating 12.5 VDC. Multiple error codes for air cleaner but none are installed. Need to return to replace 1050 thermostat. Notified office to schedule return to swap thermostat.
Palm Desert, CA - Upon arrival unit was idle with temperature satisfied. Tested and cycled. Compressor and fan motor amps are in range. Measured proper communicating 12.5 VDC. Multiple error codes for air cleaner but none are installed. Need to return to replace 1050 thermostat. Notified office to schedule return to swap thermostat.
Brayan T.
Brayan T.
Assisted tech with diagnostic. See debrief.
Palm Desert, CA 92211
Brayan T.
Brayan T.
Performed annual heating maintenance on 2) 2018 American Standard platinum split systems. Replaced 2) 20x20 filters. Both faus are located in laundry room attic access. Cleared condensation lines from clear out valves. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Everything checked out in range. 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card.
Palm Desert, CA 92260
Palm Desert, CA - Performed annual heating maintenance on 2) 2018 American Standard platinum split systems. Replaced 2) 20x20 filters. Both faus are located in laundry room attic access. Cleared condensation lines from clear out valves. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Everything checked out in range. 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card.
Palm Desert, CA - Performed annual heating maintenance on 2) 2018 American Standard platinum split systems. Replaced 2) 20x20 filters. Both faus are located in laundry room attic access. Cleared condensation lines from clear out valves. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Everything checked out in range. 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card.
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2025 American Standard gold heat pump. Upflow fau is located in hallway closet. Replaced 20x25 filter located in filter rack. Condensate pump tested operational. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, and secured electrical connections. Honeywell s200 thermostat checked out operational. Reset service reminder on thermostat. System is working properly in heating at this time of service. Gave client Starbucks gift card. Prebooked cooling maintenance on site with client.
Palm Springs, CA 92262
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2018 American Standard split system. Upflow fau is located in outdoor closet. Rinsed washable filter located in blower compartment. Cleared condensation line from fau. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Checked microamps for flame sensor. Everything checked out operational. Honeywell 8000 thermostat checked out in range. System is working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule.
Palm Springs, CA 92264
Palm Springs, CA - Performed annual heating maintenance on a 2018 American Standard split system. Upflow fau is located in outdoor closet. Rinsed washable filter located in blower compartment. Cleared condensation line from fau. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Checked microamps for flame sensor. Everything checked out operational. Honeywell 8000 thermostat checked out in range. System is working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule.
Palm Springs, CA - Performed annual heating maintenance on a 2018 American Standard split system. Upflow fau is located in outdoor closet. Rinsed washable filter located in blower compartment. Cleared condensation line from fau. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Checked microamps for flame sensor. Everything checked out operational. Honeywell 8000 thermostat checked out in range. System is working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule.
Brayan T.
Brayan T.
Performed annual heating maintenance on 2) 2019 American Standard 5ton package units. Replaced filters located in package unit. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked temperature rise. Inspected evaporator coils for cleanliness. Checked capacitors and hard start kits. Honeywell UV bulbs are still operational. Honeywell 8000 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client starbucks gift card. Booked cooling maintenance on site with client.
Palm Springs, CA 92264
Palm Springs, CA - Performed annual heating maintenance on 2) 2019 American Standard 5ton package units. Replaced filters located in package unit. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked temperature rise. Inspected evaporator coils for cleanliness. Checked capacitors and hard start kits. Honeywell UV bulbs are still operational. Honeywell 8000 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client starbucks gift card. Booked cooling maintenance on site with client.
Palm Springs, CA - Performed annual heating maintenance on 2) 2019 American Standard 5ton package units. Replaced filters located in package unit. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked temperature rise. Inspected evaporator coils for cleanliness. Checked capacitors and hard start kits. Honeywell UV bulbs are still operational. Honeywell 8000 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client starbucks gift card. Booked cooling maintenance on site with client.
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2) 2015 American Standard split systems. Upflow FAUs are located in garage and outdoor closet. Replaced customer supplied 20x25 and 16x25 filters located in blower compartments. Cleared condensation lines from faus. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service.
Rancho Mirage, CA 92270
Rancho Mirage, CA - Performed annual heating maintenance on a 2) 2015 American Standard split systems. Upflow FAUs are located in garage and outdoor closet. Replaced customer supplied 20x25 and 16x25 filters located in blower compartments. Cleared condensation lines from faus. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service.
Rancho Mirage, CA - Performed annual heating maintenance on a 2) 2015 American Standard split systems. Upflow FAUs are located in garage and outdoor closet. Replaced customer supplied 20x25 and 16x25 filters located in blower compartments. Cleared condensation lines from faus. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service.
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2015 American Standard split system. Upflow fau is located in hallway closet. Rinsed washable filter located in blower compartment. Cleared condensation line from fau. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Checked micro amps for flame sensor. Honeywell 6000 thermostat checked out operational. System is working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule cooling maintenance.
Rancho Mirage, CA 92270
Rancho Mirage, CA - Performed annual heating maintenance on a 2015 American Standard split system. Upflow fau is located in hallway closet. Rinsed washable filter located in blower compartment. Cleared condensation line from fau. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Checked micro amps for flame sensor. Honeywell 6000 thermostat checked out operational. System is working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule cooling maintenance.
Rancho Mirage, CA - Performed annual heating maintenance on a 2015 American Standard split system. Upflow fau is located in hallway closet. Rinsed washable filter located in blower compartment. Cleared condensation line from fau. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Checked micro amps for flame sensor. Honeywell 6000 thermostat checked out operational. System is working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule cooling maintenance.
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2) 2024 American Standard Platinum Heat pumps. Upflow FAUs are located in garage and outdoor mechanical closets. Replaced 2) 20x25 filters located in filter racks. Cleared condensation lines from clear out valves. Serviced garage ductless unit and rinsed washable filters. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, and found no error codes on CDAs. 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card.
Rancho Mirage, CA 92270
Rancho Mirage, CA - Performed annual heating maintenance on a 2) 2024 American Standard Platinum Heat pumps. Upflow FAUs are located in garage and outdoor mechanical closets. Replaced 2) 20x25 filters located in filter racks. Cleared condensation lines from clear out valves. Serviced garage ductless unit and rinsed washable filters. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, and found no error codes on CDAs. 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card.
Rancho Mirage, CA - Performed annual heating maintenance on a 2) 2024 American Standard Platinum Heat pumps. Upflow FAUs are located in garage and outdoor mechanical closets. Replaced 2) 20x25 filters located in filter racks. Cleared condensation lines from clear out valves. Serviced garage ductless unit and rinsed washable filters. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, and found no error codes on CDAs. 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card.
Brayan T.
Brayan T.
Performed annual heating maintenance on 3) American Standard Platinum Heat pumps. Upflow FAUs are located in indoor and outdoor closet. Replaced 14x25 and 3) 10x24 filters located in lower walls and filter rack in outdoor closet. Cleared condensation lines from clear out valves. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on CDAs, and secured electrical connections. 1050 thermostats and zoning checked out operational. Systems are working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule cooling maintenance.
Indian Wells, CA 92210
Indian Wells, CA - Performed annual heating maintenance on 3) American Standard Platinum Heat pumps. Upflow FAUs are located in indoor and outdoor closet. Replaced 14x25 and 3) 10x24 filters located in lower walls and filter rack in outdoor closet. Cleared condensation lines from clear out valves. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on CDAs, and secured electrical connections. 1050 thermostats and zoning checked out operational. Systems are working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule cooling maintenance.
Indian Wells, CA - Performed annual heating maintenance on 3) American Standard Platinum Heat pumps. Upflow FAUs are located in indoor and outdoor closet. Replaced 14x25 and 3) 10x24 filters located in lower walls and filter rack in outdoor closet. Cleared condensation lines from clear out valves. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on CDAs, and secured electrical connections. 1050 thermostats and zoning checked out operational. Systems are working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule cooling maintenance.
Brayan T.
Brayan T.
Performed annual heating maintenance on 2) American Standard Platinum Heat pumps. Upflow FAUs are located in laundry closet and guest bathroom closet. Replaced 20x25 filters located in filter racks and cleared condensation lines from clear out valves. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on CDA, and per clients request set fan modes from Circulate to AUTO. 1050 and 360 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule cooling maintenance at this time of service.
Indian Wells, CA 92210
Indian Wells, CA - Performed annual heating maintenance on 2) American Standard Platinum Heat pumps. Upflow FAUs are located in laundry closet and guest bathroom closet. Replaced 20x25 filters located in filter racks and cleared condensation lines from clear out valves. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on CDA, and per clients request set fan modes from Circulate to AUTO. 1050 and 360 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule cooling maintenance at this time of service.
Indian Wells, CA - Performed annual heating maintenance on 2) American Standard Platinum Heat pumps. Upflow FAUs are located in laundry closet and guest bathroom closet. Replaced 20x25 filters located in filter racks and cleared condensation lines from clear out valves. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on CDA, and per clients request set fan modes from Circulate to AUTO. 1050 and 360 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card. Client opted to wait to schedule cooling maintenance at this time of service.
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2026 American Standard Gold heat pump. Fau is located in hallway attic access. Replaced 20x25 and 14x14 filters. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, cleared condensation line from clear out valve, and secured electrical connections. Ecobee thermostat checked out operational. System is working properly in heating at this time of service. Gave client Starbucks gift card.
Indio, CA 92203
Indio, CA - Performed annual heating maintenance on a 2026 American Standard Gold heat pump. Fau is located in hallway attic access. Replaced 20x25 and 14x14 filters. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, cleared condensation line from clear out valve, and secured electrical connections. Ecobee thermostat checked out operational. System is working properly in heating at this time of service. Gave client Starbucks gift card.
Indio, CA - Performed annual heating maintenance on a 2026 American Standard Gold heat pump. Fau is located in hallway attic access. Replaced 20x25 and 14x14 filters. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, cleared condensation line from clear out valve, and secured electrical connections. Ecobee thermostat checked out operational. System is working properly in heating at this time of service. Gave client Starbucks gift card.
Brayan T.
Brayan T.
Installed new dome temperature sensor. Tested and cycled unit. System is cooling properly at this time of service with no error codes present.
Indio, CA 92203
Indio, CA - Installed new dome temperature sensor. Tested and cycled unit. System is cooling properly at this time of service with no error codes present.
Brayan T.
Brayan T.
Performed annual heating maintenance on 2) 2025 American Standard Platinum units. Upflow FAUs are located in the garage. Replaced 20x25 and 24x24 filters located at FAUs. Cleared condensation lines from jones valve. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on CDA, and secured electrical connections. Both 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card. Client stated errors codes on 1050 thermostat, found multiple error codes for faulty temperature sensor. Temperature sensor may be out of range and drops connection then reestablish. Assigned office sensor to average temperatures in rooms. No error codes present at this time of service.
Rancho Mirage, CA 92270
Rancho Mirage, CA - Performed annual heating maintenance on 2) 2025 American Standard Platinum units. Upflow FAUs are located in the garage. Replaced 20x25 and 24x24 filters located at FAUs. Cleared condensation lines from jones valve. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on CDA, and secured electrical connections. Both 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card. 

Client stated errors codes on 1050 thermostat, found multiple error codes for faulty temperature sensor. Temperature sensor may be out of range and drops connection then reestablish. Assigned office sensor to average temperatures in rooms. No error codes present at this time of service.
Rancho Mirage, CA - Performed annual heating maintenance on 2) 2025 American Standard Platinum units. Upflow FAUs are located in the garage. Replaced 20x25 and 24x24 filters located at FAUs. Cleared condensation lines from jones valve. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on CDA, and secured electrical connections. Both 1050 thermostats checked out operational. Both systems are working properly in heating at this time of service. Gave client Starbucks gift card. 

Client stated errors codes on 1050 thermostat, found multiple error codes for faulty temperature sensor. Temperature sensor may be out of range and drops connection then reestablish. Assigned office sensor to average temperatures in rooms. No error codes present at this time of service.
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2023 Goodman package unit. Replaced 18x18 filter located in package unit. Cycled heater from nest thermostat. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Serviced and rinsed washable filters for ductless units in man cave and casita. Everything checked out in range. Cycled unit back in cooling. Thermostat checked operational. System is working properly in heating at this time of service. Gave client Starbucks gift card and renewed HFCP paid via CC.
Rancho Mirage, CA 92270
Rancho Mirage, CA - Performed annual heating maintenance on a 2023 Goodman package unit. Replaced 18x18 filter located in package unit. Cycled heater from nest thermostat. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Serviced and rinsed washable filters for ductless units in man cave and casita. Everything checked out in range. Cycled unit back in cooling. Thermostat checked operational. System is working properly in heating at this time of service. Gave client Starbucks gift card and renewed HFCP paid via CC.
Rancho Mirage, CA - Performed annual heating maintenance on a 2023 Goodman package unit. Replaced 18x18 filter located in package unit. Cycled heater from nest thermostat. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Serviced and rinsed washable filters for ductless units in man cave and casita. Everything checked out in range. Cycled unit back in cooling. Thermostat checked operational. System is working properly in heating at this time of service. Gave client Starbucks gift card and renewed HFCP paid via CC.
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2026 American Standard Platinum heat pump. Replaced 20x30 filter located in hallway ceiling. Fau attic access is located in master closet. Cleared condensation line from clear out valve. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on 360 thermostat, and secured electrical connections. Per clients request, rewired REME HALO LED to power on when the blower motor/fan is active. Tested and cycled equipment in cooling. 360 thermostat checked out operational. System is working properly at this time of service. Gave client Starbucks gift card and prebooked cooling maintenance on site with client.
Cathedral City, CA 92234
Cathedral City, CA - Performed annual heating maintenance on a 2026 American Standard Platinum heat pump. Replaced 20x30 filter located in hallway ceiling. Fau attic access is located in master closet. Cleared condensation line from clear out valve. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on 360 thermostat, and secured electrical connections. Per clients request, rewired REME HALO LED to power on when the blower motor/fan is active. Tested and cycled equipment in cooling. 360 thermostat checked out operational. System is working properly at this time of service. Gave client Starbucks gift card and prebooked cooling maintenance on site with client.
Cathedral City, CA - Performed annual heating maintenance on a 2026 American Standard Platinum heat pump. Replaced 20x30 filter located in hallway ceiling. Fau attic access is located in master closet. Cleared condensation line from clear out valve. Followed sequence of operations and checked voltage, amperage, temperature rise, refrigerant levels, found no error codes on 360 thermostat, and secured electrical connections. Per clients request, rewired REME HALO LED to power on when the blower motor/fan is active. Tested and cycled equipment in cooling. 360 thermostat checked out operational. System is working properly at this time of service. Gave client Starbucks gift card and prebooked cooling maintenance on site with client.
Brayan T.
Brayan T.
Performed annual heating maintenance on 2) 2010 and 2012 American Standard split systems. Upflow FAUs are located in garage and mechanical closet but from door entry. Replaced 2) 12x25 and 16x25 filters. Cleared condensation lines from faus. Client cycled heaters from thermostat. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked microamps for flame sensor. Checked temperature rise. Everything checked out within range. Thermostats checked out operational. Systems are working properly in heating at this time of service. Gave client Starbucks gift card.
Palm Springs, CA 92262
Palm Springs, CA - Performed annual heating maintenance on 2) 2010 and 2012 American Standard split systems. Upflow FAUs are located in garage and mechanical closet but from door entry. Replaced 2) 12x25 and 16x25 filters. Cleared condensation lines from faus. Client cycled heaters from thermostat. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked microamps for flame sensor. Checked temperature rise. Everything checked out within range. Thermostats checked out operational. Systems are working properly in heating at this time of service. Gave client Starbucks gift card.
Palm Springs, CA - Performed annual heating maintenance on 2) 2010 and 2012 American Standard split systems. Upflow FAUs are located in garage and mechanical closet but from door entry. Replaced 2) 12x25 and 16x25 filters. Cleared condensation lines from faus. Client cycled heaters from thermostat. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked microamps for flame sensor. Checked temperature rise. Everything checked out within range. Thermostats checked out operational. Systems are working properly in heating at this time of service. Gave client Starbucks gift card.
Brayan T.
Brayan T.
Knocked on the door and rang doorbell no answer, called client who is away from home that error codes indicate that the batteries for the temperature sensor have failed. Recommended replacing batteries and if issue persist to schedule technician to return when available.
Palm Desert, CA 92211
Brayan T.
Brayan T.
Client stated condenser would trip the breaker when running at 100%. Found condenser and ductless unit sharing the same circuit breaker at the main panel. Compressor was running over max rated amps at 17.49/16 RLA with ductless unit running simultaneously. Turned off breaker for ductless unit and amperage for compressor dropped to 16.39, rinsed condenser coils and cycled power back on for ductless unit and compressor amps measured 14.84. Refrigerant levels checked out in range. System is cooling properly at this time of service. Informed client if issue reoccurs ductless unit will need to be on its own circuit and not share one with the condenser. Advised to call electrical department for quotes to have ductless unit on its own circuit if needed.
Palm Desert, CA 92211
Palm Desert, CA - Client stated condenser would trip the breaker when running at 100%. Found condenser and ductless unit sharing the same circuit breaker at the main panel. Compressor was running over max rated amps at 17.49/16 RLA with ductless unit running simultaneously. Turned off breaker for ductless unit and amperage for compressor dropped to 16.39, rinsed condenser coils and cycled power back on for ductless unit and compressor amps measured 14.84. Refrigerant levels checked out in range. System is cooling properly at this time of service. 

Informed client if issue reoccurs ductless unit will need to be on its own circuit and not share one with the condenser. Advised to call electrical department for quotes to have ductless unit on its own circuit if needed.
Palm Desert, CA - Client stated condenser would trip the breaker when running at 100%. Found condenser and ductless unit sharing the same circuit breaker at the main panel. Compressor was running over max rated amps at 17.49/16 RLA with ductless unit running simultaneously. Turned off breaker for ductless unit and amperage for compressor dropped to 16.39, rinsed condenser coils and cycled power back on for ductless unit and compressor amps measured 14.84. Refrigerant levels checked out in range. System is cooling properly at this time of service. 

Informed client if issue reoccurs ductless unit will need to be on its own circuit and not share one with the condenser. Advised to call electrical department for quotes to have ductless unit on its own circuit if needed.
Brayan T.
Brayan T.
Performed annual heating maintenance on a GE furnace with a airtemp condenser. Upflow fau is located in the garage. Replaced 20x25 filter located in filter rack. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Cleared condensation lines. Thermostat checked out operational. System is working properly in heating at this time of service. Gave client Starbucks gift card. Client stated garage ductless unit is non op and wanted a quote for a new ductless unit. Sent estimate via email for a 1.5ton unit. Reuse electrical. Ductless unit for casita is cooling properly at this time of service.
Palm Desert, CA 92211
Palm Desert, CA - Performed annual heating maintenance on a GE furnace with a airtemp condenser. Upflow fau is located in the garage. Replaced 20x25 filter located in filter rack. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Cleared condensation lines. Thermostat checked out operational. System is working properly in heating at this time of service. Gave client Starbucks gift card. 

Client stated garage ductless unit is non op and wanted a quote for a new ductless unit. Sent estimate via email for a 1.5ton unit. Reuse electrical. Ductless unit for casita is cooling properly at this time of service.
Palm Desert, CA - Performed annual heating maintenance on a GE furnace with a airtemp condenser. Upflow fau is located in the garage. Replaced 20x25 filter located in filter rack. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Cleared condensation lines. Thermostat checked out operational. System is working properly in heating at this time of service. Gave client Starbucks gift card. 

Client stated garage ductless unit is non op and wanted a quote for a new ductless unit. Sent estimate via email for a 1.5ton unit. Reuse electrical. Ductless unit for casita is cooling properly at this time of service.
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2024 American Standard Silver 3ton unit. Replaced 20x30 filter located in upper wall. Fau attic access is located in hallway. Cleared condensation line from jones valve. Followed sequence of operations and checked voltage, condenser fan motor amps, compressor start/run amps, capacitor, temperature rise, refrigerant levels, and secured all electrical connections. Per clients request adjusted supply registers in master bedroom. Cycled unit in cooling. Ecobee thermostat checked out operational. System is working properly at this time of service. Gave client Starbucks gift card. Client renewed HFCP paid via check. Client opted to wait to schedule cooling maintenance.
Palm Desert, CA 92211
Palm Desert, CA - Performed annual heating maintenance on a 2024 American Standard  Silver 3ton unit. Replaced 20x30 filter located in upper wall. Fau attic access is located in hallway. Cleared condensation line from jones valve. Followed sequence of operations and checked voltage, condenser fan motor amps, compressor start/run amps, capacitor, temperature rise, refrigerant levels, and secured all electrical connections. Per clients request adjusted supply registers in master bedroom. Cycled unit in cooling. Ecobee thermostat checked out operational. System is working properly at this time of service. Gave client Starbucks gift card. Client renewed HFCP paid via check. Client opted to wait to schedule cooling maintenance.
Palm Desert, CA - Performed annual heating maintenance on a 2024 American Standard  Silver 3ton unit. Replaced 20x30 filter located in upper wall. Fau attic access is located in hallway. Cleared condensation line from jones valve. Followed sequence of operations and checked voltage, condenser fan motor amps, compressor start/run amps, capacitor, temperature rise, refrigerant levels, and secured all electrical connections. Per clients request adjusted supply registers in master bedroom. Cycled unit in cooling. Ecobee thermostat checked out operational. System is working properly at this time of service. Gave client Starbucks gift card. Client renewed HFCP paid via check. Client opted to wait to schedule cooling maintenance.
Brayan T.
Brayan T.
Performed annual heating maintenance on 2) 2013 American Standard split systems. Replaced 2) 18x30, 14x14, and 12x12 filters. FAUs are located in hallway attic access. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Cleared condensation lines. Zoning checked out operational. Thermostats checked out okay. Systems are working properly in heating at this time of service. Gave client Starbucks gift card. Prebooked cooling maintenance on site.
Rancho Mirage, CA 92270
Rancho Mirage, CA - Performed annual heating maintenance on 2) 2013 American Standard split systems. Replaced 2) 18x30, 14x14, and 12x12 filters. FAUs are located in hallway attic access. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Cleared condensation lines. Zoning checked out operational. Thermostats checked out okay. Systems are working properly in heating at this time of service. Gave client Starbucks gift card. Prebooked cooling maintenance on site.
Rancho Mirage, CA - Performed annual heating maintenance on 2) 2013 American Standard split systems. Replaced 2) 18x30, 14x14, and 12x12 filters. FAUs are located in hallway attic access. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked and detected zero carbon monoxide. Checked temperature rise. Cleared condensation lines. Zoning checked out operational. Thermostats checked out okay. Systems are working properly in heating at this time of service. Gave client Starbucks gift card. Prebooked cooling maintenance on site.
Brayan T.
Brayan T.
Upon arrival client stated unit is dripping water inside the fau. Found water leaking from tee, condensation line p trap is clogged. Cleared condensation line and poured water down line multiple times to assure proper drainage. Recommended installing a clear out valve and a water safety switch, client declined at this time. System is cooling and draining properly at this time of service.
Rancho Mirage, CA 92270
Rancho Mirage, CA - Upon arrival client stated unit is dripping water inside the fau. Found water leaking from tee, condensation line p trap is clogged. Cleared condensation line and poured water down line multiple times to assure proper drainage. Recommended installing a clear out valve and a water safety switch, client declined at this time. System is cooling and draining properly at this time of service.
Rancho Mirage, CA - Upon arrival client stated unit is dripping water inside the fau. Found water leaking from tee, condensation line p trap is clogged. Cleared condensation line and poured water down line multiple times to assure proper drainage. Recommended installing a clear out valve and a water safety switch, client declined at this time. System is cooling and draining properly at this time of service.
Brayan T.
Brayan T.
Performed annual heating maintenance on a 2024 American Standard Gold heat pump. Fau is located in hallway attic access. Cleared condensation line from jones valve. Replaced 14x24 and 18x18 filters. Followed sequence of operations and checked voltage, condenser fan motor amps, compressor start/run amps, capacitor, hard start kit, temperature rise, refrigerant levels, secured all electrical connections. Cycled unit in cooling. Honeywell 8000 thermostat checked out operational. System is working properly in heating at this time of service. Gave client starbucks gift card. Client opted to wait to schedule cooling maintenance.
Palm Springs, CA 92262
Palm Springs, CA - Performed annual heating maintenance on a 2024 American Standard Gold heat pump. Fau is located in hallway attic access. Cleared condensation line from jones valve. Replaced 14x24 and 18x18 filters. Followed sequence of operations and checked voltage, condenser fan motor amps, compressor start/run amps, capacitor, hard start kit, temperature rise, refrigerant levels, secured all electrical connections. Cycled unit in cooling. Honeywell 8000 thermostat checked out operational. System is working properly in heating at this time of service. Gave client starbucks gift card. Client opted to wait to schedule cooling maintenance.
Palm Springs, CA - Performed annual heating maintenance on a 2024 American Standard Gold heat pump. Fau is located in hallway attic access. Cleared condensation line from jones valve. Replaced 14x24 and 18x18 filters. Followed sequence of operations and checked voltage, condenser fan motor amps, compressor start/run amps, capacitor, hard start kit, temperature rise, refrigerant levels, secured all electrical connections. Cycled unit in cooling. Honeywell 8000 thermostat checked out operational. System is working properly in heating at this time of service. Gave client starbucks gift card. Client opted to wait to schedule cooling maintenance.
Brayan T.
Brayan T.
Updated client on part, will notify office to schedule repair once part is in hand.
Indio, CA 92203