Call Now Book Service Online Estimate Specials

Amador

Amador

Maintenance Technician

Rating

Reviews

Amador has been part of the Hydes team since 2019 and is an NCI-certified maintenance technician with a strong electrical background. He is recognized for his professionalism, patience, and personable service, always taking the time to explain system conditions clearly and help customers feel confident in their home comfort. Dedicated to keeping systems operating at peak efficiency, Amador values proactive maintenance and the trust customers place in him. Outside of work, he volunteers at Southwest Church and enjoys giving back to the community.

Name: Amador

Recent Jobs and Reviews

Rated 4.9 out of 5 stars based on 2219 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation for the service provided. Customers consistently express gratitude and praise for the professionalism, knowledge, and courtesy demonstrated by the technicians. Recurring themes include exceptional customer service, with technicians being described as friendly, respectful, polite, and professional throughout their interactions. Technical expertise is another dominant positive trend, as customers frequently commend the thorough diagnostics, efficient problem-solving, and clear explanations provided during service calls. Many reviewers highlight the promptness and reliability of the service, noting quick response times, punctuality, and efficient completion of work. The dedication to resolving complex or frustrating situations is particularly appreciated, with several customers expressing relief and happiness at having their HVAC and electrical issues successfully addressed. There is also notable appreciation for the transparency and honesty in service delivery, with customers valuing straightforward communication without unnecessary upselling. Long-term customer loyalty emerges as a theme, with multiple reviewers mentioning years of positive experiences and enthusiastic recommendations to neighbors and friends. The overall tone is one of trust, satisfaction, and genuine appreciation for quality workmanship and customer-focused service.

At a glance

Hydes Air Conditioning has completed 25 jobs in September 2026.

The 15 customer reviews shown here average 5.0 out of 5.

The most recent job was on September 10, 2026.

Recent work covers Indio, CA, La Quinta, CA, Palm Desert, CA, Palm Springs, CA and Rancho Mirage, CA.

Reviews

Great
He did an excellent job and fixed everything for us.
Rodger - Indio, CA 92203
Great service!!
Stayed with the project after hours until it was fixed!
Christy - La Quinta, CA 92253
Excellent Service - Very Professional Tech
My first service visit after a March 2026 HVAC unit complete replacement. Appointment was set-up six months after the date of installation. A complete list of services to be/and performed was provided and all questions answered in the most professional manner. Thanks.
Jim - La Quinta, CA 92253
Did a great job.
John - Indio, CA 92203
Very responsive
Christy - La Quinta, CA 92253
Great service
Great 👍
George - Indio, CA 92203
x
Jamie - La Quinta, CA 92253
Excellent Service
We are so glad that we found your company. You were so highly recommended by the residents of Sun City, how could we not give you a try.
Pamela - Palm Desert, CA 92211
Excellent & Pro Service!
Amador was excellent! Diagnosed the issue & explained his findings thoroughly. A friendly & knowledgeable technician.
Beverly - Indio, CA 92201
Professional and courteous
Amador was very thorough and took the time to explain what he was going to do to fix my problem.
Melanie - Indio, CA 92201
Excellent Service. Very skilled. So kind.
John - La Quinta, CA 92253
AC shut off suddenly
Amador came, emergently, identified a frozen pipe did the necessary diagnostics and repairs, vacuumed and drained the AC Cool air returned immediately ~and I didn't have to go to a hotel! What a relief.
Martha - Rancho Mirage, CA 92270
Great job! Very very pleased with Amador!
Amador is very thorough and very careful.
Vicki - Palm Springs, CA 92264
Outstanding communication skills and service
Penny - Palm Desert, CA 92211
Service was excellent - Amadorexplained everything & showed the readings for our A/C
Les - Indio, CA 92203

Job Locations

Amador C.
Amador C.
🛠️🛠️ Demand service No cool Upon arrival, client inform me that her system was making a growling noise Client set thermostat to cool, condenser fan motor kicked on compressor growled multiple times trying to start With further investigation, it was discovered that start kit and capacitor. We’re both completely out of range. While testing equipment, it was also discovered that contactor was very pitted due to multiple attempts to start Spoke with client Recommend system rejuvenation Client approved recommended repairs 🛠️ Replaced condenser fan motor Capacitor, start kit and contactor Cycle equipment Rinse condenser coil ✅ System is now operating properly and within limit limits
Indio, CA 92203
Indio, CA - 🛠️🛠️
Demand service
No cool

Upon arrival, client inform me that her system was making a growling noise

Client set thermostat to cool, condenser fan motor kicked on compressor growled multiple times trying to start

With further investigation, it was discovered that start kit and capacitor. We’re both completely out of range.
While testing equipment, it was also discovered that contactor was very pitted due to multiple attempts to start

Spoke with client
Recommend system rejuvenation
Client approved recommended repairs

🛠️
Replaced condenser fan motor
Capacitor, start kit and contactor

Cycle equipment
Rinse condenser coil
✅
System is now operating properly and within limit limits
Indio, CA - 🛠️🛠️
Demand service
No cool

Upon arrival, client inform me that her system was making a growling noise

Client set thermostat to cool, condenser fan motor kicked on compressor growled multiple times trying to start

With further investigation, it was discovered that start kit and capacitor. We’re both completely out of range.
While testing equipment, it was also discovered that contactor was very pitted due to multiple attempts to start

Spoke with client
Recommend system rejuvenation
Client approved recommended repairs

🛠️
Replaced condenser fan motor
Capacitor, start kit and contactor

Cycle equipment
Rinse condenser coil
✅
System is now operating properly and within limit limits
Amador C.
Amador C.
🛠️🛠️ Demand service S#25172MWFJG POV system LR Upon arrival, inform me of a rumbling noise coming from return vent Went up to the attic for further investigation. It was undiscovered a piece of liner, causing noise issue. Remove liner set system on test mode Checked equipment settings at circuitboard ✅ Equipment is operating properly and within limits No more rumbling noise
La Quinta, CA 92253
La Quinta, CA - 🛠️🛠️
Demand service
S#25172MWFJG
POV system LR

Upon arrival, inform me of a rumbling noise coming from return vent

Went up to the attic for further investigation. It was undiscovered a piece of liner, causing noise issue.
Remove liner set system on test mode
Checked equipment settings at circuitboard
✅
Equipment is operating properly and within limits
No more rumbling noise
La Quinta, CA - 🛠️🛠️
Demand service
S#25172MWFJG
POV system LR

Upon arrival, inform me of a rumbling noise coming from return vent

Went up to the attic for further investigation. It was undiscovered a piece of liner, causing noise issue.
Remove liner set system on test mode
Checked equipment settings at circuitboard
✅
Equipment is operating properly and within limits
No more rumbling noise
Amador C.
Amador C.
🛠️🛠️ Unit SN ****E20751 Master bedroom Replacing OEM communicating board and inverter drive Carrier communicating system Before repairs check for any electrical shortages that may cost inverter drive to short out Check compressor verified plug, and windings weren’t grounding Installed circuit boards program and properly commission to equipment Cycle system on cool and verified system operation Check fan motor, compressor, amps, and refrigerant pressures. ✅ System is now cooling properly and within limits
Palm Springs, CA 92264
Palm Springs, CA - 🛠️🛠️
Unit SN ****E20751
Master bedroom 

Replacing OEM communicating board and inverter drive
Carrier communicating system

Before repairs check for any electrical shortages that may cost inverter drive to short out
Check compressor verified plug, and windings weren’t grounding

Installed circuit boards program and properly commission to equipment
Cycle system on cool and verified system operation
Check fan motor, compressor, amps, and refrigerant pressures.

✅
System is now cooling properly and within limits
Palm Springs, CA - 🛠️🛠️
Unit SN ****E20751
Master bedroom 

Replacing OEM communicating board and inverter drive
Carrier communicating system

Before repairs check for any electrical shortages that may cost inverter drive to short out
Check compressor verified plug, and windings weren’t grounding

Installed circuit boards program and properly commission to equipment
Cycle system on cool and verified system operation
Check fan motor, compressor, amps, and refrigerant pressures.

✅
System is now cooling properly and within limits
Amador C.
Amador C.
🛠️🛠️ Demand service No cool Upon arrival, client inform me that system was not cooling Thermostat was taped up to the wall With further investigation, it was discovered that thermostat was not properly seated on back plate Mobile home, wood panel, when attempting to put thermostat on the wall, the panel sink in Client just moved into property Spoke with client and recommend performing first maintenance this way I can get an overview of all of the equipment While performing maintenance found compressor was pulling high amps due to a dirty condenser coil Refrigerant and all other components were within range Rinsed equipment and replaced two 16 x 20 filters Also recommend replacing thermostat (thermostat conflict back plate) After maintenance and thermostat install installation ✅ System is now operating properly and within limits
Thousand Palms, CA 92276
Thousand Palms, CA - 🛠️🛠️
Demand service
No cool

Upon arrival, client inform me that system was not cooling
Thermostat was taped up to the wall

With further investigation, it was discovered that thermostat was not properly seated on back plate
Mobile home, wood panel, when attempting to put thermostat on the wall, the panel sink in

Client just moved into property
Spoke with client and recommend performing first maintenance this way I can get an overview of all of the equipment
While performing maintenance found compressor was pulling high amps due to a dirty condenser coil
Refrigerant and all other components were within range
Rinsed equipment and replaced two 16 x 20 filters

Also recommend replacing thermostat (thermostat conflict back plate)
After maintenance and thermostat install installation

✅
System is now operating properly and within limits
Thousand Palms, CA - 🛠️🛠️
Demand service
No cool

Upon arrival, client inform me that system was not cooling
Thermostat was taped up to the wall

With further investigation, it was discovered that thermostat was not properly seated on back plate
Mobile home, wood panel, when attempting to put thermostat on the wall, the panel sink in

Client just moved into property
Spoke with client and recommend performing first maintenance this way I can get an overview of all of the equipment
While performing maintenance found compressor was pulling high amps due to a dirty condenser coil
Refrigerant and all other components were within range
Rinsed equipment and replaced two 16 x 20 filters

Also recommend replacing thermostat (thermostat conflict back plate)
After maintenance and thermostat install installation

✅
System is now operating properly and within limits
Amador C.
Amador C.
🛠️🛠️ Revised System Operations – Previous Repair * Opened evaporator coil and verified TXV metering device. * Replaced restricted filter-drier * Re-glued condensation line couplers; found and repaired minor leaks. * ⚠️ System took longer than normal to pump down, raising concern about compressor operation. * Pulled vacuum, pressure-tested filter-drier fittings, and reintroduced refrigerant. * Compressor overheated during startup. Cooled compressor and washed dirty condenser coils. * System restarted and stabilized at 63°F vapor saturation / 179 PSIG suction / 10A compressor amps. * ✅ Achieved a 20° temperature split at the furnace. 🗣️ Client Communication * Explained that the system is currently operating and cooling as expected mechanically. * ⚠️ Advised that high suction pressure and vapor saturation temperature remain abnormal. * Also explained that the extended pump-down time may indicate the compressor is not operating at full capacity. Previous tech pointed out some iss
La Quinta, CA 92253
La Quinta, CA - 🛠️🛠️ Revised System Operations – Previous Repair

* Opened evaporator coil and verified TXV metering device.

* Replaced restricted filter-drier

* Re-glued condensation line couplers; found and repaired minor leaks.
* ⚠️ System took longer than normal to pump down, raising concern about compressor operation.

* Pulled vacuum, pressure-tested filter-drier fittings, and reintroduced refrigerant.
* Compressor overheated during startup. Cooled compressor and washed dirty condenser coils.
* System restarted and stabilized at 63°F vapor saturation / 179 PSIG suction / 10A compressor amps.
* ✅ Achieved a 20° temperature split at the furnace.

🗣️ Client Communication

* Explained that the system is currently operating and cooling as expected mechanically.
* ⚠️ Advised that high suction pressure and vapor saturation temperature remain abnormal.
* Also explained that the extended pump-down time may indicate the compressor is not operating at full capacity.

Previous tech pointed out some iss
La Quinta, CA - 🛠️🛠️ Revised System Operations – Previous Repair

* Opened evaporator coil and verified TXV metering device.

* Replaced restricted filter-drier

* Re-glued condensation line couplers; found and repaired minor leaks.
* ⚠️ System took longer than normal to pump down, raising concern about compressor operation.

* Pulled vacuum, pressure-tested filter-drier fittings, and reintroduced refrigerant.
* Compressor overheated during startup. Cooled compressor and washed dirty condenser coils.
* System restarted and stabilized at 63°F vapor saturation / 179 PSIG suction / 10A compressor amps.
* ✅ Achieved a 20° temperature split at the furnace.

🗣️ Client Communication

* Explained that the system is currently operating and cooling as expected mechanically.
* ⚠️ Advised that high suction pressure and vapor saturation temperature remain abnormal.
* Also explained that the extended pump-down time may indicate the compressor is not operating at full capacity.

Previous tech pointed out some iss
Amador C.
Amador C.
🛠️🛠️ Demand service No cool Upon arrival thermostat was set to cool, blower motor kicked on Went to outdoor condenser and found that system was not working After further investigation, it was discovered system had a weak capacitor Called client informed her of findings Client approved Only charge for labor I was here about two weeks ago. Revised previous repair and verified that everything is operating as it should Check refrigerant AS A COURTESY Rinsed condenser coil very dirty ✅ System is operating properly and within limits
Palm Desert, CA 92211
Palm Desert, CA - 🛠️🛠️
Demand service
No cool

Upon arrival thermostat was set to cool, blower motor kicked on
Went to outdoor condenser and found that system was not working

After further investigation, it was discovered system had a weak capacitor
Called client informed her of findings
Client approved
Only charge for labor I was here about two weeks ago.

Revised previous repair and verified that everything is operating as it should
Check refrigerant

AS A COURTESY
Rinsed condenser coil very dirty 

✅
System is operating properly and within limits
Palm Desert, CA - 🛠️🛠️
Demand service
No cool

Upon arrival thermostat was set to cool, blower motor kicked on
Went to outdoor condenser and found that system was not working

After further investigation, it was discovered system had a weak capacitor
Called client informed her of findings
Client approved
Only charge for labor I was here about two weeks ago.

Revised previous repair and verified that everything is operating as it should
Check refrigerant

AS A COURTESY
Rinsed condenser coil very dirty 

✅
System is operating properly and within limits
Amador C.
Amador C.
⚒️⚒️ DEMAND SERVICE – NO COOL 🔧 Customer Concern: Follow-up visit for system still not cooling after the evaporator coil was replaced earlier in the day. 🔍 Diagnostics: • Checked refrigerant pressures — pressures were excessively high. • Rinsed condenser coil and monitored pressures — pressures remained high. • Inspected evaporator coil, filters, and return ductwork, including attic air intake — no airflow issues found. • Further inspection revealed the evaporator coil had no TXV metering device installed; no piston/filter assembly was present. 🛠️ Repair: • Pumped down the system. • Separated refrigerant tubing and confirmed missing metering device. • Installed TXV and restored system operation. ✅ Final Results: System is now operating properly and within manufacturer operating limits.
La Quinta, CA 92253
La Quinta, CA - ⚒️⚒️ DEMAND SERVICE – NO COOL

🔧 Customer Concern:
Follow-up visit for system still not cooling after the evaporator coil was replaced earlier in the day.

🔍 Diagnostics:
• Checked refrigerant pressures — pressures were excessively high.
• Rinsed condenser coil and monitored pressures — pressures remained high.
• Inspected evaporator coil, filters, and return ductwork, including attic air intake — no airflow issues found.
• Further inspection revealed the evaporator coil had no TXV metering device installed; no piston/filter assembly was present.

🛠️ Repair:
• Pumped down the system.
• Separated refrigerant tubing and confirmed missing metering device.
• Installed TXV and restored system operation.

✅ Final Results:
System is now operating properly and within manufacturer operating limits.
La Quinta, CA - ⚒️⚒️ DEMAND SERVICE – NO COOL

🔧 Customer Concern:
Follow-up visit for system still not cooling after the evaporator coil was replaced earlier in the day.

🔍 Diagnostics:
• Checked refrigerant pressures — pressures were excessively high.
• Rinsed condenser coil and monitored pressures — pressures remained high.
• Inspected evaporator coil, filters, and return ductwork, including attic air intake — no airflow issues found.
• Further inspection revealed the evaporator coil had no TXV metering device installed; no piston/filter assembly was present.

🛠️ Repair:
• Pumped down the system.
• Separated refrigerant tubing and confirmed missing metering device.
• Installed TXV and restored system operation.

✅ Final Results:
System is now operating properly and within manufacturer operating limits.
Amador C.
Amador C.
🛠️🛠️ Demand service Upon arrival Client asked to relight his water heater ✅ re-lit water heater ✅ checked refrigerant 1.5 ✅ ductless temperature System is operating properly and within limits Water heater is also heating water
Indio, CA 92203
Amador C.
Amador C.
❄️🧊 Preformed a semi annual cooling service on split heat POV Replace 20 x 30 filter/ceiling mounted Condenser located on ground Cycle equipment follow cooling sequence of operation check refrigerant, and pressures Thermostat checked out OK Check fan motor and compressor amps Cleared condensation line from outside Rinsed condenser coil ✅ Cooling equipment, checked out operational at this visit.
La Quinta, CA 92253
Amador C.
Amador C.
🛠️🛠️ Returned to check system Opened evaporator coil preformed electronic leak detector, Visual leak detector and tested unions with blue Nothing was found no oil on condensation pan Went to condenser Removed condenser top, perform an electronic leak search, visual inspection search and tested unions with blue Nothing was found Pumped down system Pressurize, refrigerant lines, and evaporator coil with nitrogen a add pressure sensors on suction and liquid lines Will return in three days to inspect gauges for pressure loss Called homeowner informed him of today’s tasks Will follow up with client on Friday to get access to property
La Quinta, CA 92253
La Quinta, CA - 🛠️🛠️
Returned to check system 

Opened evaporator coil preformed electronic leak detector,
Visual leak detector and tested unions with blue 
Nothing was found no oil on condensation pan

Went to condenser
Removed condenser top, perform an electronic leak search, visual inspection search and tested unions with blue
Nothing was found

Pumped down system
Pressurize, refrigerant lines, and evaporator coil with nitrogen
a add pressure sensors on suction and liquid lines
Will return in three days to inspect gauges for pressure loss

Called homeowner informed him of today’s tasks
Will follow up with client on Friday to get access to property
La Quinta, CA - 🛠️🛠️
Returned to check system 

Opened evaporator coil preformed electronic leak detector,
Visual leak detector and tested unions with blue 
Nothing was found no oil on condensation pan

Went to condenser
Removed condenser top, perform an electronic leak search, visual inspection search and tested unions with blue
Nothing was found

Pumped down system
Pressurize, refrigerant lines, and evaporator coil with nitrogen
a add pressure sensors on suction and liquid lines
Will return in three days to inspect gauges for pressure loss

Called homeowner informed him of today’s tasks
Will follow up with client on Friday to get access to property
Amador C.
Amador C.
Received only communicating board Need inverter board Client is paying for over night delivery Attached is a new estimate please sign and accept We are holding a spot for Wednesday afternoon If part does not arrive to manufacturer within working hours, we are also holding a spot for Thursday morning
Palm Springs, CA 92264
Amador C.
Amador C.
⚒️⚒️ Demand service No Cool Upon a rebel, Client informed me that system was taking a long time to reach desired temperature Thermostat was calling for cooling displaying indoor temperature at 82° Went to auto equipment for further investigation check all moving components and then found that system was 2 pounds low on refrigerant Spoke with Client , Client approved balancing refrigerant ✅ System is now operating properly and within limits
Indio, CA 92203
Amador C.
Amador C.
🛠️🛠️ Demand service No cool Upon arrival, client directed me to Casita , thermostat was set for 75° Indoor temperature 90+ degrees Indoor blower was working, but only blowing room temperature out of the vents Went to outdoor equipment where it was discovered that system had tripped a breaker due to bad capacitor and start kit Installed components to test equipment, re-energize unit and system started working Spoke with client-client approved necessary repairs ✅ System is now operating properly and within limit As a courtesy replace 18 x 18 filter See Notes
Rancho Mirage, CA 92270
Amador C.
Amador C.
❄️🧊 Performed a semi annual cooling service On two units Replace filters throughout the house nest thermostat check out OK Cycle equipment follow cooling sequence of operation check refrigerant, and pressures Checked capacitor, fan motor, compressor, amps and voltage Cleared condensation lines Rinsed condenser coils Renewed membership Booked winter maintenance ✅ Equipment checked out operation operational, and within limit limits
Palm Springs, CA 92264
Amador C.
Amador C.
🛠️🛠️ Demand service No cool No cool Upon arrival, property manager directed me to thermostat / blank thermostat Went up to the equipment for further investigation It was then discovered ❌ blown low voltage fuse ❌ shorted, contactor ❌ shorted thermostat 📞 Spoke with homeowner over the phone informed him of the findings Client approved recommended repairs ✅ replaced low voltage fuel ✅ replaced contactor ✅ replaced thermostat After repairs were made cycled equipment and verified system operations and temperature split ✅ Equipment is now operating properly and within the limit
Palm Springs, CA 92264
Amador C.
Amador C.
On arrival system was working properly Set thermostat on and off everything was working If fan stays on again client will call the office
Indio, CA 92201
Amador C.
Amador C.
🛠️🛠️ Demand service no cool Unit system # N436-A Bedroom system Upon arrival, client inform me that bedroom system was making a noise that was coming from the attic, also the previous day technician added 4 pounds of refrigerant and again today system is not maintaining temperature Set thermostat to cool went to upper equipment and found system out of refrigerant Went out to the attic for further investigation and found a leak on coil SpokeWith client on finding and the next steps to getting issue resolved Will order coil from carrier and follow up with client on ETA
La Quinta, CA 92253
Amador C.
Amador C.
🛠️🛠️ Unit SN ***** 2205 Upon arrival, client informed me the back bedroom was not cooling Thermostat was set to cool but only blowing room temperature out of the vent Went to outdoor equipment, found system, not engaging due to pressure switch After revising pressures, it was done determined the system was flat on refrigerant Courtesy Went up to the attic identified system, and was able to find leak in evaporated coil Presented client with repair options, but recommend replacing equipment due to age of equipment and reliability Client approved system replacement office. Will follow up with client for installation.
Indian Wells, CA 92210
Amador C.
Amador C.
Reset and re-programmed Honeywell thermostats for dining, lobby and tennis areas Educated on thermostat settings partially looked
Palm Desert, CA 92211
Amador C.
Amador C.
🛠️🛠️ Demand service No cool Air handler SN****MLMJG Living room system Upon arrival, client directed me to the living room unit, thermostat was blank Went up to the attic for further investigation and found loose fuse bracket Time all low-voltage connections and high voltage connections Reset equipment and verified system operation Bedroom thermostat set for 75 and reading 80° Went to condenser and check in charge on both units ✅ Both unit units are operating properly and within limit limits 🗣️ Client communication: Informed client that return was taking air from living room area, causing temperature to rise at bedroom thermostat However, after I was done, diagnosing equipment bedroom temperature had already started to drop
Palm Desert, CA 92211
Amador C.
Amador C.
🛠️🛠️ Demand service Thermostat issue Upon arrival, client inform me that thermostat was acting funny Reset thermostat and verified system operations Thermostat has a screen screensaver, screen goes dark and indoor temperature bounces around the screen that’s normal Educated neighbor on how thermostat works System is operating properly and within limits Client paid Trip charge Warranty pays diagnostic
Indio, CA 92203
Amador C.
Amador C.
🛠️🛠️ Noise issue Upon arrival client informed me that system makes a noise at night when it’s quiet ( system operates at lower speed) Replaced customers supply filters Went up to the attic for further investigation, shook air handler Move air handler away from trusses check airflow, checked for manual dampers. Also make sure that refrigerant lines weren’t touching evaporator cover. System was set on test mode System is operating smooth and quiet at this time Ask client to move register lever when he hears that noise. It might be a register issue. ✅ System is operating properly and within limits
Indio, CA 92203
Amador C.
Amador C.
🛠️🛠️ Noise issues 2026 gold system Informed client the way gold system works, variable speed on compressor and blower motor, system operation is normal. Compressor is ramping up and down as it should. ✅ System is operating properly and within manufacture specifications
Indio, CA 92201
Amador C.
Amador C.
❄️🧊 Two Lennox split systems 2018 and 2020 / 4 ton Cleared condensation lines, tested water, safety switches and replaced 16 x 25 filters located within the furnace/garage up-flows Cycle equipment followed, cooling sequence of operations Checked capacitor, fan motor, compressor, amps, and a voltage Secured and clean electrical connections at condenser and fuse box Check refrigerator pressures Thermostats checked out OK Rinsed both condensers ✅ Cooling equipment checked out operational at this visit
Palm Desert, CA 92211
Amador C.
Amador C.
🛠️🛠️ Demand service Noise issue Upon arrival, client informed me that one air conditioner kicks on there’s a noise that comes from the attic Dropped thermostat 5° to engage second stage cooling After blower motor ramps up a thump came from the attic Went to the attic/air handler for further diagnosing Removed filter from register cycle system on and off multiple times It was determined that filter was so restricted it was causing Platinum box to suck in After filter was replaced noise went away ✅ System is now operating properly and within limits
Indio, CA 92201