Rating
Reviews
Name: Israel Beltran
College: He graduated from Mayfield College (HVAC) and has certifications in HVAC, EPA, forklift operator and business management.
Favorite Aspect of My Job: Izzy’s favorite aspect of his job is being able to learn new things about HVAC and the ability to do ten things at once.
Hobbies: When he is not working and supervising at Hydes, Izzy enjoys spending time with family and hobbies that include, sports, cars and music.
Interesting Fact About Me: Israel a.k.a. “Izzy” has been a part of the Hydes work family for over two years although he has worked in the HVAC industry for seven years.
Customers say: The reviews exhibit a positive overall sentiment, with a majority of customers expressing satisfaction with the services provided by Hyde's AC. The recurring themes include praise for the technicians' expertise, professionalism, and courtesy. Customers also appreciate the prompt and efficient service, with many highlighting the technicians' ability to address issues quickly and effectively. Additionally, the company's reputation for honesty, integrity, and quality workmanship is frequently mentioned. Negative reviews are present but are outweighed by the positive ones. The negative reviews primarily focus on minor issues or misunderstandings, with customers expressing gratitude for the prompt resolution of their concerns. Overall, the sentiment is positive, with customers expressing satisfaction with the company's services and technicians.
We were having an issue with our new thermostat. This guy checked everything and solved the issue. Amazing and knowledgeable service guy 🙏🙏🥳🥳
You’re Guys are good guys! Friendly, considerate and pretty darn knowledgeable! I’m SUPER HAPPY that we do business with Hyde’s! Thank you GUYS
Response from Hydes Air Conditioning:
Thank you for your business, David, and we appreciate the great review!
The service technician Brandon O was very thorough . He spotted a very concerning situation with the capacitor during his service inspection of our AC unit . He explained all the details and the situation was remedied. We are leaving for the summer and this service gave us the piece of mind we needed. Thank you Brandon for your good work
Response from Hydes Air Conditioning:
Thank you for the great review!
As always, great service.
Courteous and professional, and friendly. Arrived on time and explained the details of the service he was to perform. Great service
Izzy is extremely knowledgeable and well experienced in HVAC systems.
So far so good I believe he’ll be an asset to your company
Izzy was excellent and very personable
Very efficient and informative.
Very friendly and knowledgeable…
Israel (and everyone at Hydes) were great communicators, they explained everything they were doing, what would happen next, asked if I had questions, genuinely cared that I had a good customer experience! Efficient, tidy, great installation, I’m really happy with the work that was done - replacing your entire HVAC system is a big investment and I’m happy I used Hydes!
on time and quick
Service Type: Demand Service Technician Summary: Upon arrival, the client reported that the living room thermostat was displaying a temperature reading noticeably lower than the actual room temperature. The client had placed three independent temperature sensors adjacent to the thermostat, all showing a discrepancy of approximately 5°F above the thermostat reading. To verify the issue, I used my own calibrated temperature sensors and placed them directly on top of the thermostat. The results confirmed the client’s observation, showing a consistent 5°F difference. A supervisor arrived on site to assist with diagnostics. Together, we conducted multiple tests on both HVAC units. We verified the full cooling sequence of operations for each unit and confirmed that both systems are operating according to the manufacturer’s specifications. To resolve the issue, we replaced the Ecobee thermostat. Before departing, I rechecked the temperature readings. The new thermostat’s reading aligned c
Found thermostat frozen would not respond to touch—-pull thermostat from wall reinstall—-since he thermostat now communicating with Client 2000 miles away-checked configure mode everything configured properly— see photos
Air Conditioning System Repairs: Replaced a cracked drain pan in a leaking AC unit. Ensured proper drainage and protected the home from water damage.
Outdoor Lighting Repairs: Replaced a malfunctioning ballast in the outdoor lighting system. Restored full functionality and consistent illumination for safety and aesthetics.
Per conversation with Client and technician water is continuing to run out Secondary condensate drain line ——air handlers in the attic—— upon inspection of drain lines found primary drain line plugged past trap and breathing port—— cut primary drain line passed the last 90 to have straight shot to outside termination—— primary drain line finally cleared after two or three efforts of compressed air—-see photos—— redid primary drain line with 45 instead of 90s (existing line had hard 90s right next to each other hindering a good condensate line clear)) installed new trap Jones valve breathing port and riser—-treating call as a follow up from a maintenance visit.. Client to call in cc number
Generator does not have 5 feet in front of exhaust, also generator control is not working properly. Does not let me scroll using the arrow keys up and down did not do maintenance due to those issues.
Upon arrival found outdoor unit not running—-faulty high voltage fuse— disconnect box in bad shape/faulty——-replaced disconnect box—— install two new fuses—-system is up and running
Wired condenser directly to supply wires on subpanel wirenut them together and disconnected mini split condenser to see what happens if nothing trips breaker then will return to install disconnect box for main condenser run new circuit to mini split with its own disconnect box on wall next to line set cover
Could not do maintenance, generator was not properly installed and control cover melted due to heat not being exhausted,wall to close to exhaust vent
Generator is exercising as it should be on time
This call is a follow up from the maintenance visit late last month Thermostat off-line no Internet connection——-networks would not pop up on screen ——reboot, thermostat by removing from back plate—-after rebooting thermostat came back to manufacturer specifications
See invoice for 05–23-2025
Maintenance visit cooling—-filter changed reference 24 x 30 —-refrigerant levels per manufacture specification reference temperature differential—-condensate line cleared—-all motors were running per manufacturer specification—-will need to return and clean outdoor coil no hose on truck—-check tighten electrical disconnect box clean electrical panel at unit
Tighten condenser caps in front of city inspector
Replace battery and fuse generator running at this time
This was a follow up visit —-from demand call on May 24—-master bedroom unit serial number 4179—- as per previous technician high side service valve is leaking and system is low on refrigerant—— unable to get high side service valve to close without leaking —-small leak, but it is leaking—-will send estimate for high side-service valve replacement and refrigerant add—— system holds 11 pounds of R 22, which is no longer manufactured —-R22 replacement Refrigerant is very difficult to locate due to new reclamation laws.—— invoice sent per email on file—
Maintenance cooling 2 units ——changed filters—-running amps on outdoor fan and compressor with specifications --run capacitor tested with specification— clean condenser and cleared condensation— both systems are good
Maintenance cooling ——change filters—-running amps on outdoor fan and compressor with specification--run capacitor tested with specification--contractor is burnt and notified customer, quoted them for a new contractor customer agreed— replace contractor with a new one—— check pressure and Freon(R-22)— condenser and cleared condensate line— bring two extra filter for next maintenance customer asked
Started generator idols, lean like it needs fuel. Second start it cranks, but never runs, third start only cranks, fourth start no crank. Cause may be bad relay and ignition, module or wiring from the magneto from the solenoid. May need to return with Barry.
Gateway was not installed at initial install Client supplied gateway Was able to get both 8000 thermostats connected to clients phone
Maintenance cooling 2 units——changed filters—-running amps on outdoor fan and compressor with specification --cleared condensate lines—- washed units
Client has been having issues with system =eerr
Maintenance cooling ——change filters—-running amps on outdoor fan and compressor with specification--run capacitor tested with specification--blowed Condensation lined—- washed unit
Maintenance cooling ——change filters—-running amps on outdoor fan and compressor with specification--run capacitor tested bad burnt as well, burnt wiring from the contact to the capacitor notified customer—-gave estimate to customer they approved—- replaced the capacitor and wiring—— clean condenser and cleared condensate line
Install astronomical timer for outdoor lighting