Jonathan

Jonathan

Service Technician

Rating

Reviews

Jonathan has been part of the Hydes team since 2020 and has worked in the HVAC industry since 2007. Born and raised in the Coachella Valley, he brings local knowledge and years of technical experience to every service call. He is NATE certified, the highest standard in the HVAC industry, reflecting his expertise and dedication to professional excellence. Known among his colleagues as a reliable teammate who steps in wherever needed, Jonathan is also valued by customers for his professionalism, honesty, and persistence in solving problems, whether it’s a complicated repair, an emergency call, or simply taking the time to explain options clearly. Outside of work, he enjoys life with his wife and two young boys, trips to the beach, and good Mexican food.

Name: Jonathan

Certifications: NATE

Recent Jobs and Reviews

Rated 5.0 out of 5 stars based on 2402 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation for the service provided. Customers consistently express gratitude and praise for the professionalism, knowledge, and courtesy demonstrated by the technicians. Recurring themes include exceptional customer service, with technicians being described as friendly, respectful, polite, and professional throughout their interactions. Technical expertise is another dominant positive trend, as customers frequently commend the thorough diagnostics, efficient problem-solving, and clear explanations provided during service calls. Many reviewers highlight the promptness and reliability of the service, noting quick response times, punctuality, and efficient completion of work. The dedication to resolving complex or frustrating situations is particularly appreciated, with several customers expressing relief and happiness at having their HVAC and electrical issues successfully addressed. There is also notable appreciation for the transparency and honesty in service delivery, with customers valuing straightforward communication without unnecessary upselling. Long-term customer loyalty emerges as a theme, with multiple reviewers mentioning years of positive experiences and enthusiastic recommendations to neighbors and friends. The overall tone is one of trust, satisfaction, and genuine appreciation for quality workmanship and customer-focused service.

At a glance

Hydes Air Conditioning has completed 25 jobs in October 2026.

The 15 customer reviews shown here average 5.0 out of 5.

The most recent job was on October 8, 2026.

Recent work covers Palm Desert, CA, Palm Springs, CA, Rancho Mirage, CA, Cathedral City, CA and Indio, CA.

Reviews

Excellent service
Prompt, kind, respectful and efficient
Darryl - Palm Desert, CA 92260
Fantastic service
I only went with your company because Johnathon did such a wonderful job. In fact, I mainly called Hyde’s for a price quote because I’d planned to stay with my current company for the HVAC replacement.
Ross - Palm Springs, CA 92262
100% pleased
Our technician was extremely knowledgeable and efficient. Old-fashioned, courtesy, and kindness alongside fair pricing is a rare to these days. But so much appreciated.
Mylee - Palm Desert, CA 92211
Excellent salesperson/tech.
He’s great. Was very thorough and clear in providing estimates. It is expensive and cost will be major part of determining factor whether to go with Hyde’s or other (still in process of getting estimates).
Ron - Palm Desert, CA 92211
Excellent service call
Good detail information from Jonathan so issues could be understood
Nick - Palm Desert, CA 92211
Very thorough and on time!
Always a pleasure to have Hyde’s technicians in — prompt, responsive and very thorough
Tom - Indian Wells, CA 92210
Excellent Service
Jonathan was very thorough and helpful.
Gregory - Cathedral City, CA 92234
Great service
Thermostats were connected to WiFi. Technician was very knowledgeable and did a great job.
Niki - Rancho Mirage, CA 92270
Excellent and educational
Knowledgeable and handled difficult questions with assurance.
Ross - Palm Springs, CA 92262
Hydes is always the best
I have been using Hyde’s for the last eight years and there has never been an issue with their service— always on time, professional, knowledgeable and polite. I give them five stars
Norman - Cathedral City, CA 92234
Knowledgeable
Johnathan took the time to find out what the problem was. He stayed until he was sure that it would not shut down again and he checked everything. He made sure that he explained what happened and made us feel assured that the situation would not happen again.
Steven - Rancho Mirage, CA 92270
Service
Pamela - Indio, CA 92201
Excellent service
Very professional, explained everything in terms that I was able to understand. Great price
Steven - Rancho Mirage, CA 92270
Outstanding service
Jonathan was extremely polite, friendly and helpful. I cannot say enough positive things about my experience with Jonathan as well as other Hyde’s technicians who have worked in my home. 5 stars all around!
Sue - La Quinta, CA 92253
Jonathan Carrier is an excellent technician, he’s very knowledgeable and honest, I will always request him for my services.
Yvonne - Palm Desert, CA 92211

Job Locations

Jonathan C.
Jonathan C.
Ordered new fan motor from Howard for kitchen. Noise continues
Palm Springs, CA 92262
Jonathan C.
Jonathan C.
Ecm blower motor installed by general air recently diagnosed doing same thing. Blower motor starts then slows down then runs properly. Equipment is receiving proper voltage. Recommend replacing motor. Equipment new and client and is under warranty though advised we do not warranty Daiken. Client wants to wait until motor stops then will replace motor. Advise we can replace motor at full price then homeowner can wait for reimbursement from manufacturer. Do to motor working at this time decision is to wait.
Bermuda Dunes, CA 92203
Jonathan C.
Jonathan C.
We are installing new unit next door home owner owns two properties. Attempted to use thermostat from other house and wiring incorrectly. Removed jumper between w and y. Unit operating though advise is in very poor condition. Home is unoccupied
Palm Desert, CA 92211
Palm Desert, CA - We are installing new unit next door home owner owns two properties. Attempted to use thermostat from other house and wiring incorrectly. Removed jumper between w and y. Unit operating though advise is in very poor condition. Home is unoccupied
Palm Desert, CA - We are installing new unit next door home owner owns two properties. Attempted to use thermostat from other house and wiring incorrectly. Removed jumper between w and y. Unit operating though advise is in very poor condition. Home is unoccupied
Jonathan C.
Jonathan C.
Equipment working on arrival. Checked compressor amps, capacitors, refrigerant, blower motor are operating. Client notices unit shuts off then starts again. Pressure switch’s tested good. Advised equipment is working properly though is in poor condition. Client elderly on very fixed income and wanting to wait on replacement. Recommended continued maintenance service
Palm Desert, CA 92211
Palm Desert, CA - Equipment working on arrival. Checked compressor amps, capacitors, refrigerant, blower motor are operating. Client notices unit shuts off then starts again. Pressure switch’s tested good. Advised equipment is working properly though is in poor condition. Client elderly on very fixed income and wanting to wait on replacement. Recommended continued maintenance service
Palm Desert, CA - Equipment working on arrival. Checked compressor amps, capacitors, refrigerant, blower motor are operating. Client notices unit shuts off then starts again. Pressure switch’s tested good. Advised equipment is working properly though is in poor condition. Client elderly on very fixed income and wanting to wait on replacement. Recommended continued maintenance service
Jonathan C.
Jonathan C.
Uploaded video of knocking sound recording home owner recorded. Sn 6yjf-2 ton for kitchen. No noise on site. Check fan blade. Opened top and checked inside condenser for rubbing of blade. Cycle operation multiple times on off and no noise at this time. Client to monitor
Palm Springs, CA 92262
Palm Springs, CA - Uploaded video of knocking sound recording home owner recorded. Sn 6yjf-2 ton for kitchen. No noise on site. Check fan blade. Opened top and checked inside condenser for rubbing of blade. Cycle operation multiple times on off and no noise at this time. Client to monitor
Palm Springs, CA - Uploaded video of knocking sound recording home owner recorded. Sn 6yjf-2 ton for kitchen. No noise on site. Check fan blade. Opened top and checked inside condenser for rubbing of blade. Cycle operation multiple times on off and no noise at this time. Client to monitor
Jonathan C.
Jonathan C.
Fan mode continues to stay on when off. Repaired electrical short.
Cathedral City, CA 92234
Jonathan C.
Jonathan C.
Performed annual maintenance on 2019 upflow gas furnace American standard split system. Changed out 20x25 filter upstairs. Fau located upstairs in basement. Cleared out condensation line to drain properly. Followed sequence of operations gas valve, safety switches, blower motor speeds, and flame ignitor. Temperature rise 45 degrees. Nest checked operational. Maintenance ductless unit filters and coils. Client renewed comfort plan. System is operating properly at this time of service
Palm Desert, CA 92260
Jonathan C.
Jonathan C.
Performed diagnostic on bedroom system sn-7959. Equipment iceing up on arrival. Diagnostic found blower motor over heated, coils iceing up do to no airflow. Replaced blower motor capacitor, blower motor started operating. Blower motor off balance and wobbling, overheating which advise will eventually fail to operate, recommend replacing motor. Equipment in very poor condition well past life expectancy with multiple and issues. Advised equipment uses r22 refrigerant which is no longer manufactured. Recommend routine maintenance on equipment. Recommend equipment replacement. Attached repair and replacement options below.
Rancho Mirage, CA 92270
Rancho Mirage, CA - Performed diagnostic on bedroom system sn-7959. Equipment iceing up on arrival. Diagnostic found blower motor over heated, coils iceing up do to no airflow. Replaced blower motor capacitor, blower motor started operating. Blower motor off balance and wobbling, overheating which advise will eventually fail to operate, recommend replacing motor.
 Equipment in very poor condition well past life expectancy with multiple and issues. Advised equipment uses r22 refrigerant which is no longer manufactured. Recommend routine maintenance on equipment. 
Recommend equipment replacement. Attached repair and replacement options below.
Rancho Mirage, CA - Performed diagnostic on bedroom system sn-7959. Equipment iceing up on arrival. Diagnostic found blower motor over heated, coils iceing up do to no airflow. Replaced blower motor capacitor, blower motor started operating. Blower motor off balance and wobbling, overheating which advise will eventually fail to operate, recommend replacing motor.
 Equipment in very poor condition well past life expectancy with multiple and issues. Advised equipment uses r22 refrigerant which is no longer manufactured. Recommend routine maintenance on equipment. 
Recommend equipment replacement. Attached repair and replacement options below.
Jonathan C.
Jonathan C.
Verified equipment is working at this time. Will order and return to replace registers. Also client wanting to complete installation of ductless unit from previous estimate with Mike. Resent estimate for electrical
Palm Desert, CA 92211
Palm Desert, CA - Verified equipment is working at this time. Will order and return to replace registers. Also client wanting to complete installation of ductless unit from previous estimate with Mike. Resent estimate for electrical
Palm Desert, CA - Verified equipment is working at this time. Will order and return to replace registers. Also client wanting to complete installation of ductless unit from previous estimate with Mike. Resent estimate for electrical
Jonathan C.
Jonathan C.
Contacted client and will schedule to install
Palm Springs, CA 92262
Jonathan C.
Jonathan C.
3 systems Percision tune up. Cleaned and replaced filters on roof. Verified refrigerant pressures are good. Verified electrical connections are secure. Cleared drain lines, verified drain lines are secure and draining properly. Checked compressors, front office has stopped cooling and then starts cooling again. York package unit - sn-9961 which serves front office compressor running in very high amps 20 amps Rla requires below 16 amps. Compressor stops running due to over heating which advise indicates compressor is failing. Equipment is 2006 in poor condition well past life expectancy. Equipment uses r22 refrigerant which is no longer manufactured. Recommend replacement of equipment to prevent continuous breakdowns. Attached estimate below also emailed for equipment replacement
Palm Desert, CA 92211
Palm Desert, CA - 3 systems Percision tune up. Cleaned and replaced filters on roof. Verified refrigerant pressures are good. Verified electrical connections are secure. Cleared drain lines, verified drain lines are secure and draining properly. Checked compressors, front office has stopped cooling and then starts cooling again. York package unit - sn-9961 which serves front office compressor running in very high amps 20 amps Rla requires below 16 amps. Compressor stops running due to over heating which advise indicates compressor is failing. Equipment is 2006 in poor condition well past life expectancy. Equipment uses r22 refrigerant which is no longer manufactured. Recommend replacement of equipment to prevent continuous breakdowns. Attached estimate below also emailed for equipment replacement
Palm Desert, CA - 3 systems Percision tune up. Cleaned and replaced filters on roof. Verified refrigerant pressures are good. Verified electrical connections are secure. Cleared drain lines, verified drain lines are secure and draining properly. Checked compressors, front office has stopped cooling and then starts cooling again. York package unit - sn-9961 which serves front office compressor running in very high amps 20 amps Rla requires below 16 amps. Compressor stops running due to over heating which advise indicates compressor is failing. Equipment is 2006 in poor condition well past life expectancy. Equipment uses r22 refrigerant which is no longer manufactured. Recommend replacement of equipment to prevent continuous breakdowns. Attached estimate below also emailed for equipment replacement
Jonathan C.
Jonathan C.
Verified equipment is working properly according to manufacturer specifications. Replaced filters, cleared drain lines. Ver
Rancho Mirage, CA 92270
Jonathan C.
Jonathan C.
Sighned up on maintenance plan. Repaired vibration noise inside furnace. Verified sequence of operation is working properly at this time. Installed new filter complimentary. Advised to schedule next maintenance service.
Palm Desert, CA 92211
Palm Desert, CA - Sighned up on maintenance plan. Repaired vibration noise inside furnace. Verified sequence of operation is working properly at this time. Installed new filter complimentary. Advised to schedule next maintenance service.
Palm Desert, CA - Sighned up on maintenance plan. Repaired vibration noise inside furnace. Verified sequence of operation is working properly at this time. Installed new filter complimentary. Advised to schedule next maintenance service.
Jonathan C.
Jonathan C.
Property manager provided access. Contacted home owner on phone and advised on options,
La Quinta, CA 92253
La Quinta, CA - Property manager provided access. Contacted home owner on phone and advised on options,
La Quinta, CA - Property manager provided access. Contacted home owner on phone and advised on options,
Jonathan C.
Jonathan C.
Advised on current rebates and equipment options. Client currently uses Vic’s and wanted second opinion.
Indio, CA 92201
Indio, CA - Advised on current rebates and equipment options. Client currently uses Vic’s and wanted second opinion.
Indio, CA - Advised on current rebates and equipment options. Client currently uses Vic’s and wanted second opinion.
Jonathan C.
Jonathan C.
Verified refrigerant pressures are good. Found oil inside true suction valve. Tightened spreader valve.
Indio, CA 92203
Indio, CA - Verified refrigerant pressures are good. Found oil inside true suction valve. Tightened spreader valve.
Indio, CA - Verified refrigerant pressures are good. Found oil inside true suction valve. Tightened spreader valve.
Jonathan C.
Jonathan C.
Renewed maintenance plan. Performed heater service and safety check. Verified equipment is working properly according to manufacturer specifications. Replaced filters. Verified gas and electrical connections are secure. No carbon dioxide detected.
Palm Desert, CA 92211
Jonathan C.
Jonathan C.
4-hvac mechanical inspections on 2003 York equipment. 2 ton for casita, two 3 tons and one 5 ton serving main home. Verified sequence of operation on each system. Verified refrigerant pressures are within manufacture specifications. Advise equipment uses r22 refrigerant which has been phased out and is not manufactured. Verified compressor, fan motor and blower motors are operational at this time. Equipment in very poor condition well past life expectancy, with multiple potential breakdowns due to age though is operational at this time. Inspected attic flex ductwork systems are sealed and connected. Verified ductwork systems are in good condition no major areas of concern. Verified attic insulation is in good condition. Verified electrical circuits to mechanical equipment in good condition with proper gauge wiring to each unit. Verified each mechanical system is on independent electrical circuits. Recommend replacement of HVAC equipment do to poor condition well past life expectanc
La Quinta, CA 92253
La Quinta, CA - 4-hvac mechanical inspections on 2003 York equipment. 2 ton for casita, two 3 tons and one 5 ton serving main home. Verified sequence of operation on each system. Verified refrigerant pressures are within manufacture specifications. Advise equipment uses r22 refrigerant which has been phased out and is not manufactured. Verified compressor, fan motor and blower motors are operational at this time. Equipment in very poor condition well past life expectancy, with multiple potential breakdowns due to age though is operational at this time. 

Inspected attic flex ductwork systems are sealed and connected. Verified ductwork systems are in good condition no major areas of concern. Verified attic insulation is in good condition. Verified electrical circuits to mechanical equipment in good condition with proper gauge wiring to each unit. Verified each mechanical system is on independent electrical circuits. 

Recommend replacement of HVAC equipment do to poor condition well past life expectanc
La Quinta, CA - 4-hvac mechanical inspections on 2003 York equipment. 2 ton for casita, two 3 tons and one 5 ton serving main home. Verified sequence of operation on each system. Verified refrigerant pressures are within manufacture specifications. Advise equipment uses r22 refrigerant which has been phased out and is not manufactured. Verified compressor, fan motor and blower motors are operational at this time. Equipment in very poor condition well past life expectancy, with multiple potential breakdowns due to age though is operational at this time. 

Inspected attic flex ductwork systems are sealed and connected. Verified ductwork systems are in good condition no major areas of concern. Verified attic insulation is in good condition. Verified electrical circuits to mechanical equipment in good condition with proper gauge wiring to each unit. Verified each mechanical system is on independent electrical circuits. 

Recommend replacement of HVAC equipment do to poor condition well past life expectanc
Jonathan C.
Jonathan C.
Maintenance and safety check on Maytag equipment and Goodman equipment mix matched with newer off brand innovair for bedrooms area. Home under construction currently unoccupied. Replaced filters, cleared drain lines. Bedroom equipment non operational, repaired electrical short and equipment started operating. Verified equipment is operational at this time Equipment in poor condition, found excessive construction dust and debris inside mechanical equipment which advise will decrease equipment efficiency. Inspection of ductwork found ductwork in very poor condition (see photos). Ductwork falling apart and will eventually start leaking air into attic. Advised equipment uses 410a refrigerant which is no longer manufactured. Bedroom equipment has sighns of mold in return air platform (see photos) Highly recommend equipment replacement do to existing equipment in poor condition past life expectancy to avoid multiple potential breakdowns during summer. Recommend replacing ductwork in attic
Indian Wells, CA 92210
Indian Wells, CA - Maintenance and safety check on Maytag equipment and Goodman equipment mix matched with newer off brand innovair for bedrooms area. Home under construction currently unoccupied. Replaced filters, cleared drain lines. Bedroom equipment non operational, repaired electrical short and equipment started operating. Verified equipment is operational at this time

Equipment in poor condition, found excessive construction dust and debris inside mechanical equipment which advise will decrease equipment efficiency. Inspection of ductwork found ductwork in very poor condition (see photos). Ductwork falling apart and will eventually start leaking air into attic. Advised equipment uses 410a refrigerant which is no longer manufactured. Bedroom equipment has sighns of mold in return air platform (see photos)

Highly recommend equipment replacement do to existing equipment in poor condition  past life expectancy to avoid multiple potential breakdowns during summer. Recommend replacing ductwork in attic
Indian Wells, CA - Maintenance and safety check on Maytag equipment and Goodman equipment mix matched with newer off brand innovair for bedrooms area. Home under construction currently unoccupied. Replaced filters, cleared drain lines. Bedroom equipment non operational, repaired electrical short and equipment started operating. Verified equipment is operational at this time

Equipment in poor condition, found excessive construction dust and debris inside mechanical equipment which advise will decrease equipment efficiency. Inspection of ductwork found ductwork in very poor condition (see photos). Ductwork falling apart and will eventually start leaking air into attic. Advised equipment uses 410a refrigerant which is no longer manufactured. Bedroom equipment has sighns of mold in return air platform (see photos)

Highly recommend equipment replacement do to existing equipment in poor condition  past life expectancy to avoid multiple potential breakdowns during summer. Recommend replacing ductwork in attic
Jonathan C.
Jonathan C.
Verified equipment is working properly according to manufacturer specifications. Checked filters are new and in good condition. Set up Wi-Fi on phone app.
Palm Desert, CA 92260
Jonathan C.
Jonathan C.
No one home, family member provided access. Emailed estimate for full system replacement for bedroom unit. Existing equipment in very poor condition. Recommend full system replacement
Cathedral City, CA 92234
Cathedral City, CA - No one home, family member provided access. Emailed estimate for full system replacement for bedroom unit. Existing equipment in very poor condition. Recommend full system replacement
Cathedral City, CA - No one home, family member provided access. Emailed estimate for full system replacement for bedroom unit. Existing equipment in very poor condition. Recommend full system replacement
Jonathan C.
Jonathan C.
Performed a heating maintenance on a 2013 American Standard gas furnace located inside closet. Replaced a 20x25 filter. Cycled heating equipment, checked temp split and heat rise. Verified volts and amps. Checked all safety switches. Found no carbon monoxide detected. Cleared condensation line and cleaned burner compartment. Heating system is operational at this time.
Palm Desert, CA 92260
Palm Desert, CA - Performed a heating maintenance on a 2013 American Standard gas furnace located inside closet. Replaced a 20x25 filter. Cycled heating equipment, checked temp split and heat rise. Verified volts and amps. Checked all safety switches. Found no carbon monoxide detected. Cleared condensation line and cleaned burner compartment. Heating system is operational at this time.
Palm Desert, CA - Performed a heating maintenance on a 2013 American Standard gas furnace located inside closet. Replaced a 20x25 filter. Cycled heating equipment, checked temp split and heat rise. Verified volts and amps. Checked all safety switches. Found no carbon monoxide detected. Cleared condensation line and cleaned burner compartment. Heating system is operational at this time.
Jonathan C.
Jonathan C.
Diagnostic on over/under Goettle package unit. Equipment fan motor failed and is non operational causing compressor to over heat. Found equipment full of organic growth inside coil compartment (attached photos below). Blower motor extremely dirty and overheating. Equipment uses r22 refrigerant which advise is no longer manufactured. Advised fan motor will require replacement to start though advise equipment may have additional problems do to poor condition. Home is tenant occupied, contacted home owner over phone and advised on repair and replacement options. Recommend equipment replacement do to existing equipment in very poor condition to avoid continuous breakdowns. Attached two options below for fan motor and full system replacement. Financing is available.
Palm Desert, CA 92211
Palm Desert, CA - Diagnostic on over/under Goettle package unit. Equipment fan motor failed and is non operational causing compressor to over heat. Found equipment full of organic growth inside coil compartment (attached photos below). Blower motor extremely dirty and overheating. Equipment uses r22 refrigerant which advise is no longer manufactured. Advised fan motor will require replacement to start though advise equipment may have additional problems do to poor condition. 

Home is tenant occupied, contacted home owner over phone and advised on repair and replacement options. Recommend equipment replacement do to existing equipment in very poor condition to avoid continuous breakdowns. Attached two options below for fan motor and full system replacement. Financing is available.
Palm Desert, CA - Diagnostic on over/under Goettle package unit. Equipment fan motor failed and is non operational causing compressor to over heat. Found equipment full of organic growth inside coil compartment (attached photos below). Blower motor extremely dirty and overheating. Equipment uses r22 refrigerant which advise is no longer manufactured. Advised fan motor will require replacement to start though advise equipment may have additional problems do to poor condition. 

Home is tenant occupied, contacted home owner over phone and advised on repair and replacement options. Recommend equipment replacement do to existing equipment in very poor condition to avoid continuous breakdowns. Attached two options below for fan motor and full system replacement. Financing is available.
Jonathan C.
Jonathan C.
Heating service and safety check on 2025 Lennox equipment. Replaced filters located inside mechanical closet in garage. Verified gas and electrical connections are secure. Verified gas pressure is good. Drain lines are clear, recommend jones valves in future service to clear drain lines properly existing systems share one drain line. Verified heating sequence of operation is working properly according to manufacturer specifications. No surge protection on equipment or main electrical panel. Recommend whole home surge protection to prevent damage equipment caused by power surges. Attached estimate below for surge protection also emailed.
Palm Springs, CA 92264
Palm Springs, CA - Heating service and safety check on 2025 Lennox equipment. Replaced filters located inside mechanical closet in garage. Verified gas and electrical connections are secure. Verified gas pressure is good. Drain lines are clear, recommend jones valves in future service to clear drain lines properly existing systems share one drain line. Verified heating sequence of operation is working properly according to manufacturer specifications. 
No surge protection on equipment or main electrical panel. Recommend whole home surge protection to prevent damage equipment caused by power surges. Attached estimate below for surge protection also emailed.
Palm Springs, CA - Heating service and safety check on 2025 Lennox equipment. Replaced filters located inside mechanical closet in garage. Verified gas and electrical connections are secure. Verified gas pressure is good. Drain lines are clear, recommend jones valves in future service to clear drain lines properly existing systems share one drain line. Verified heating sequence of operation is working properly according to manufacturer specifications. 
No surge protection on equipment or main electrical panel. Recommend whole home surge protection to prevent damage equipment caused by power surges. Attached estimate below for surge protection also emailed.
Jonathan C.
Jonathan C.
Second opinion on 2010 Lennox. Previous company said to replace unit due to low voltage wires sun rotting. Verified sequence of operation is working properly at this time. Home is tenant occupied. Advised home owner over phone. Equipment is past life expectancy though is operational. Recommend routine maintenance plan to keep equipment clean and operating. Repaired low voltage wires and re insulated refrigeration lines. Attached estimate below for maintenance plan
Palm Springs, CA 92264
Palm Springs, CA - Second opinion on 2010 Lennox. Previous company said to replace unit due to low voltage wires sun rotting. Verified sequence of operation is working properly at this time. Home is tenant occupied. Advised home owner over phone. Equipment is past life expectancy though is operational. Recommend routine maintenance plan to keep equipment clean and operating. Repaired low voltage wires and re insulated refrigeration lines. Attached estimate below for maintenance plan
Palm Springs, CA - Second opinion on 2010 Lennox. Previous company said to replace unit due to low voltage wires sun rotting. Verified sequence of operation is working properly at this time. Home is tenant occupied. Advised home owner over phone. Equipment is past life expectancy though is operational. Recommend routine maintenance plan to keep equipment clean and operating. Repaired low voltage wires and re insulated refrigeration lines. Attached estimate below for maintenance plan