Coachella Valley Service Area
Hydes is Indio’s Top Rated Electrical and HVAC Service Company. If you live near the Coachella Valley area, look to the map to see if we service your home.
Choose a city below and see what your neighbors are saying about our Electrician, Indoor Air Quality, Heating & Cooling repair, installation and maintenance services.
Excellent Service As Always | Deirdre D. Palm Desert, CA
"As an almost 40-year client of Hydes, my air conditioning/heating systems have been efficiently installed and maintained by three generations of Hydes. Their excellent service and cost-effective recommendations have always been appreciated. The office personnel and on-site service technicians are well-mannered and knowledgeable. I have replaced my air conditioning/heating system several times over the years and have been pleased with the outcome of the installation, the efficiency of the equipment and resulting cost savings. Thank you Hydes management & staff."
See What Customers Are Saying on Google
Recent Jobs and Reviews in Indio, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation. Customers consistently praise the professionalism, knowledge, and friendliness of the service technicians, highlighting their ability to explain technical issues clearly and in understandable terms. A recurring theme is the promptness and efficiency of service, with multiple reviewers noting quick response times, same-day appointments, and rapid problem resolution—particularly impressive given the urgency of air conditioning needs in desert heat conditions. The technicians are frequently described as courteous, personable, and professional, with customers appreciating their thorough work, attention to detail, and lack of aggressive upselling tactics. Many reviews emphasize the company's reliability and punctuality, with technicians arriving on time and completing work efficiently. The positive sentiment extends to the company as a whole, with customers expressing loyalty and trust built over years of service. Overall, the tone is enthusiastic and grateful, with customers feeling well-served by knowledgeable professionals who communicate effectively, work diligently, and provide excellent customer care. The recurring themes of expertise, friendliness, efficiency, and reliability paint a picture of a highly regarded service provider that consistently meets and exceeds customer expectations.
Job Locations and Reviews
Upon client stated downstairs system S-5983 blowing ambient air. Found outdoor fan running and compressor trying to turn on. Found failed capacitor. Installed new duel run capacitor and tested. Systems are 20 years old. Bill job
Attempted to call 2x times again and no answer. Already left message with member informing him of questions regarding building wall around condenser.
Upon arrival, member stated the equipment has intermittently stopped cooling and would only resume operation after cycling power to the outdoor unit. Reviewed system fault history at the communicating thermostat and found repeated error codes 185.01 and 185.02, with a subsequent 184 hard lockout. Cleared stored fault history through the CDA and cycled equipment for testing. Verified equipment restarted and monitored operation through compressor ramp-up. Checked refrigerant pressures, superheat, and subcooling while equipment was operating. Verified indoor air filter is clean and performed a visual inspection of accessible ductwork with no obvious airflow restrictions noted. Accessed inverter control diagnostics and verified live operating data, including compressor demand, compressor speed, EEV position, outdoor fan operation, and compressor dome temperature. Performed factory diagnostic procedure by measuring compressor dome temperature sensor voltage between J1 pin 1 and J1 pin 10 at
Upon arrival I found system off. Turned system on and found condenser runs, but not furnace blower not running. Control Board is calling for signal. Tested motor and with motor tester and found motor still doesn’t come on. Will need to call Goodman in the morning.
Can't remember and gave you information in regards to building wall for condensing unit
Upon arrival, member stated the system was not keeping up with the current heat load. Performed a full diagnostic and verified refrigerant levels, finding the system approximately 1 lb low on R-410A. Added 1 lb of R-410A and verified refrigerant pressures and operating conditions were within manufacturer specifications after charging. Performed a complete electrical inspection of the equipment and verified all electrical components were operating properly and within acceptable ranges. Further inspection found the 16x25 air filter heavily congested, restricting airflow. Also found condensate overflowing into the secondary drain due to a restriction in the primary condensate drain. Cleared the primary drain from the exterior termination, installed a Jones valve to improve future maintenance access, and flushed the drain through the Jones valve to verify proper drainage. Confirmed the primary drain is now flowing properly with no further signs of overflow. Verified a 19°F temperature spli
Upon arrival found indoor and outdoor unit were operational. Phone system overcharge even after letting refrigerant go so cool is in good condition. Super heat is a little high, possibly a restriction in system after speaking with supervisor. Before sending an estimate would like to come back to residence to try one more test that way we can send the correct estimate and get part that needs to be replaced changed out. Called the homeowner and informed homeowner. Client did not answer at this time. We have office put back on route for tomorrow.
Upon arrival, client stated he has thermostat set at at 79° but will not go below 82. While check in refrigerant levels discovered system had higher superheat and suction line temperature. Adjust TXV bulb inside attic system system superheat drop 20° and Sabyan line temperature dropped 14°. Clients are gonna monitor systems cooling and if any issues call us back.
Equipment working on arrival. Performed diagnostic and tested operation. Compressor running in high amps Rla is 20.8 and unit is running at 20 amps. Compressor is designed to run at 16.64-no mor then 18 amps. Advised compressor is running though is running in high amps which causes compressor to over heat. Compressor will run again until it over heats then turn off to cool down. Advised if equipment continues to over amp compressor will eventually fail. Equipment is cooling at this time.
Upon arrival, the unit was making a knocking noise. We had previously installed a new condenser fan motor on July 7. Inspected the fan to determine if the blade was contacting any part of the unit, but found no interference. We then removed the fan blade to further inspect the motor and confirmed the issue is coming from the condenser fan motor itself. The motor is faulty and will need to be replaced under warranty.