AC Repair, Installation & Electrician Services Near Coachella, CA
Hydes AC promises customer service that exceeds the expectations of Coachella, CA residents. Since 1972 we've been the trusted name in HVAC and electrician services for thousands of local residents. From AC repair to electrical installation, we do it all and we'd love to earn your business! See what your neighbors are saying about our services below and give us a call at (760) 360-2202 .
Local Reviews
for Coachella, CA
Our Reviews by City
Excellent Service
Jerry - Coachella, CA 92236
Bryan was very professional, polite, and respectful. He was fast, efficient, and knowledgeable.
CoachellaCA92236 33.695-116.205



Good service
Margaret - Coachella, CA 92236
Good
CoachellaCA92236 33.665-116.175



Electric Related Repair
Jose Luis - Coachella, CA 92236
Mr. Ysiano is knowledgeable, accurate and swift. He did a perfect job, and he is very friendly. Be assured you will get your money's worth.
CoachellaCA92236 33.665-116.175



Great service Alex
Delilah - Coachella, CA 92236
Alex was responsive to all my questions not matter how tedious they were. Thank you.
CoachellaCA92236 33.6675-116.19



Great service.
Josue - Coachella, CA 92236
Very professional and quick install without any issues.
CoachellaCA92236 33.7-116.21



Great service
Margaret - Coachella, CA 92236
CoachellaCA92236 33.665-116.175




Great service
Margaret - Coachella, CA 92236
CoachellaCA92236 33.665-116.175




Great service
Margaret - Coachella, CA 92236
CoachellaCA92236 33.665-116.175




Great service
Margaret - Coachella, CA 92236
CoachellaCA92236 33.665-116.175




Great Service
Brenda - Coachella, CA 92236
CoachellaCA92236 33.7-116.205




Excelente
Roberto - Coachella, CA 92236
CoachellaCA92236 33.665-116.1675




Detailed services
Delilah - Coachella, CA 92236
Alex was great to speak with made me feel confident on how to keep my AC working 💯
CoachellaCA92236 33.6675-116.19



Great service, and out standing customer satisfaction
Jerry M - Coachella, CA 92236
Maurice, was excellent. He was friendly and polite. He was knowledgeable and efficient. While in our home he was respectful and careful while working in all areas. I would highly recommend him as a service person.
CoachellaCA92236 33.695-116.205



very professional
Tony - Coachella, CA 92236
Hydes A/C company has well trained technicians,
CoachellaCA92236 33.675-116.1775



Informative Technician
Larry - Coachella, CA 92236
I feel Daniel Hydde was very knowledgeable, professional, and courteous in his interaction with me.
CoachellaCA92236 33.665-116.2



Great service
Brenda - Coachella, CA 92236
CoachellaCA92236 33.7-116.205




Excelente
Roberto - Coachella, CA 92236
CoachellaCA92236 33.665-116.1675




Knowledgeable, professional, courteous, and personable
Larry Salas - Coachella, CA 92236
I was very impressed with Barry's approach and interaction with me. He was expressive, confident, and reassuring that made me feel that I could trust that the air conditioning unit he was recommending would be the right one for my family and me.
CoachellaCA92236 33.665-116.2



Great Service
Delilah - Coachella, CA 92236
Arrived between the schedule hours. Great at explaining the product and services.
CoachellaCA92236 33.6675-116.19



Great service
Jesse - Coachella, CA 92236
Johnny was very professional and did a great job !
CoachellaCA92236 33.6825-116.18



Greatest service and awesome prices
Enrique - Coachella, CA 92236
Excellent company. Great experience.
CoachellaCA92236 33.6975-116.21



Very good service
Brenda - Coachella, CA 92236
CoachellaCA92236 33.7-116.205




Awesome price.
Enrique - Coachella, CA 92236
Great customer service. Very friendly and Very knowledgeable.
CoachellaCA92236 33.6975-116.21



Awesome service
Lorie - Coachella, CA 92236
Great customer service explained everything he was doing
CoachellaCA92236 33.68-116.16



Great service
Christopher - Coachella, CA 92236
CoachellaCA92236 33.6825-116.2075




James B.
Performed annual AC maintenance on two Goodman split systems one split heat pump with first company coil. Changed 20 x 20 x 1 and 20 x 30 x 1 filters. Check amps, volt, capacitor, and start kit. Check, refrigerant levels, superheat, so cool, line temperature in temperature split. Flushed condensation line and washed condensing coil. Found all electrical components on refrigerant levels to be with the manufacturer specifications. Both systems are operating and cooling properly at time of service.
Maurice B.
Performed heating maintenance on 2020 split heat pump system and two 2017 split heat pump systems. Filters are located throughout building, 20 x 20 x 1, verify, proper sequence of operation, check, volts and amps, checked capacitors, checked refrigerant levels and line temperatures and cycled systems. Found all three systems starting amps out of specifications recommend compressor saver kits to put amps back into range and prolong light up compressor and prevent further damage to internal windings, also found system serial number 9B2G and HR2F capacity out of range recommend replacing capacitors under parts warranty, also disconnect box for serial number 9B2G is corroded and broken disconnect hard wired system for temporary use.all thermostats checked out OK removed schedule from thermostat for office request, all three systems were heating and operating properly at this time of service. Will send estimates for repairs.
James B.
Three system maintenance. See moes debrief for details and estimate for recommended repairs
Taylor H.
I Performed Maintenance on the 2Heating System. Also replaced a 20x25 filter. The system is a 2010 model located in the hallway closet. I also flushed the condensate drain. I found that the blower motor compartment is dirty and would strongly recommend pulling and cleaning the blower motor compartment. I cleaned compartment as best as I could in place, but would definitely recommend removing and cleaning more thoroughly. Sent client estimate to do the work. The Heating System checked out operational at the time of the service.
Brayan T.
Performed annual heating maintenance on a 2022 American Standard Silver Heat Pump. Client had replaced 20x30 filter located in upstairs hallway prior to arrival. Followed sequence of operations and checked voltage, amperage, capacitor, temperature rise, and cleared condensation lines. Everything checked out in range. Thermostat checked out operational. System is working at manufacture specifications in heating at this time of service.
Amador C.
2007/ 5 ton Mantenimiento de calenton. Cambie filtro 20x30/ cielo. No monoxido de carbona. Amperage y funciones de seguridad / funcionando. Limpie calenton, y plataforma. Libbe linea de condensation. Preform semiannual getting service on carrier split system. FAU in attic. Laundry room access. Follow sequence of operation checked heater safety features. Thermostat checked out OK replace 20 x 30 filter/ceiling. Cleared condensation line.Heating equipment checked out operational
Amador C.
2022/ 3 ton Preformed a semi annual heating service on American standard split heat/ POV. Cleared condensation line and replaced 16x25 filter located within the air handler/ indoor hallway closet. Honeywell 8000 thermostat checked out ok. Checked refrigerant/ temperature split. Verified air handler is properly programmed. Heating system checked out operational at this visit. Updated equipment to city code requirements. Added water safety switch
Frank V.
2009 ,,,Check heating system everything is working within manufacturing specifications strongly recommended safety switches to prevent water back up from condenser sent estimate
Johnny Y.
Replace two duplex receptacles.
Alex N.
Performed annual maintenance in heat on ac pro 90 percent split gas, followed sequence of operation changed filters cleared condensation lines checked amps voltage limit switches safety switches cycled burners cleared burners and mechanical components fau is working to manufacture specification in heat

Barry S.
Estimate
Thor J.
Replace OEM circuit board and test system. Replaced circuit board. Verified again pressure switch is working and starting open and no voltage to inducer. Replaced circuit board and system fired up right away. Cycled a few times and system is heating properly with proper voltage and heat rise (50) supply temp of 120. Sealed open viewing hole on furnace panel to prevent debris and dust going onto circuit board. Verified card with wife and charged card visa #8998. Sending video. System has 16x25 filter and room for 5” filter rack.
Thor J.
Bryant gas furnace has error code 31 pressure switch never opened. Tested pressure switch, 27 volts across and OL for continuity , pressure switch starts open , board does not send 120v to inducer. No 120v at board for inducer but 120v at L1 and neutral. Bad board, will order and give quote/repair eta tomorrow 1/19/23.
Alex N.
Performed monthly maintenance in heat on a 2003 American standard split gas, followed sequence of operation changed filter cleared condensation line checked amps voltage limit switches safety switches cycled burners cleared burners and mechanical components fau is working to manufacture specification in heat
Alex N.
Performed annual maintenance in heat on a 2022 5 ton American standard, followed sequence of operation cleared condensation line checked amps voltage capacitor temperature split working at range changed filters, condenser is working to manufacture specification in heat, apon arrival home sad there is a noise coming from air handler took cabin panel off and sealed it unit is now working to manufacture specification
Amador C.
Ran 8 wire thermostat trough conduit FAU to condenser, cycled equipment on heat and cooling/ equipment is now operating as designed. Client paid $530.00 cash
Alex N.
Asst amador
Miguel M.
Performed a heating maintenance on a 2021 American Standard heat pump system. Cleaned return register grill and replaced a 20x30 filter located in hallway ceiling. Checked temperature heat rise, verified voltages and amperages on all electrical components. Tested capacitor and is still within range. Heating system is operational at this time. Briefly spoke with client about adding a return register for a guest bedroom. This will help cool the room better in the summer time and stop the 20x30 filter from getting sucked in. Will send estimate via email. Heating system is operational at this time.
Amador C.
Ohmed wires and found one wire grounded/ thermostat wire has 3 wires, spoke with daughter and explained what was going on/ we will be running new thermostat wire. Ran temporary thermostat wire/ cycled equipment everything is operating.
James B.
Upon arrival found system calling for heat but unit not responding. With further inspection I discovered system had a blown low-voltage fuse. Checked all low-voltage wires and changed fuse. Due to low voltage wires been in good condition I changed contactor. System is now operating properly.
Amador C.
Upon arrival found blown low-voltage fuse with further investigation found two wires touched at thermostat connection/cleaned all connectors and verified no wires were touching replaced fuse and cycled equipment. Performed a semiannual heating service on 2021 American standard/POV heat pump. Cleared condensation line 20x25 filter is clean located within the air handler/hallway access ( didn’t have replacement filter will bring extra one next visit). Checked condenser refrigerant and capacitor. Rinsed condenser. Heating equipment checked out operational at this visit. Find up on Hydes family comfort plan.
Michael H.
Estimate options.
Thor J.
Found casita 2004 York heat pump not running. Found white rogers thermostat blank. Replaced calcified batteries with homeowner provided batteries and thermostat tuned on and cycled system in cooling. System is cooling with 18 degree split. Informed homeowner about condition of system. Recommended Hyde’s annual maintenance plan to keep all their ac units in clean working condition and to be able to catch components at or near the point of failure. System uses r22 Freon and life expectancy is 10-15 years in the desert so system is on borrowed time.
Christopher C.
Found blown transformer. Low voltage short located in pressure switches. Bypassed pressure switch and found low suction/saturation. Found air filter extremely restrictive. Changed filter. Found still low saturation and low suction indicating dirty evap coil. Advised client of repairs and options. Client would rather invest in new system than clean the coil. Looking to replace this winter. System is cooling at this time.
Maurice B.
Upon arrival found blower motor only running but condenser was not upon further inspection found a system with a bad 80/5 µF capacitor, removed and replaced and tested a new 80/5 µF capacitor also added compressor saver kit to help compressor at start. System is now cooling and operating properly.