Excellent Service As Always | Deirdre D. Palm Desert, CA
"As an almost 40-year client of Hydes, my air conditioning/heating systems have been efficiently installed and maintained by three generations of Hydes. Their excellent service and cost-effective recommendations have always been appreciated. The office personnel and on-site service technicians are well-mannered and knowledgeable. I have replaced my air conditioning/heating system several times over the years and have been pleased with the outcome of the installation, the efficiency of the equipment and resulting cost savings. Thank you Hydes management & staff."
See What Customers Are Saying on Google
Recent Jobs and Reviews in Indio, CA
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, knowledge, and efficiency demonstrated by the service technicians. There is a strong recurring theme of promptness and timeliness, with many reviewers noting quick response times, same-day or next-day appointments, and technicians arriving as scheduled. The technical expertise of the staff is frequently praised, with customers highlighting thorough diagnostics, clear explanations of repairs and options, and problems being resolved quickly and effectively. Interpersonal qualities are also emphasized throughout, with reviewers describing technicians as polite, personable, kind, respectful, and helpful. Many customers appreciate the honest communication and transparency they received regarding their HVAC issues and repair options. The company's reliability is another positive trend, with loyal customers expressing continued trust in the service across multiple properties. Several reviews convey a sense of relief and happiness at having their air conditioning problems resolved efficiently, particularly during extreme heat conditions. The tone is enthusiastic and grateful, with customers feeling well-cared-for and confident in the quality of workmanship and customer service provided.
Job Locations and Reviews
Upon arrival found Lennox unit calling for cool but only condenser fan motor and blower motor operating compressor was not operating. Checked recently installed capacitor and start kit. Both components are good and well within range. Also checked compressor windings for continuity and discovered compressor winding was open and compressor overheated. Cooled off compressor, but compressor still would not start. We will be returning Monday to recheck compressor, giving compressor more time to fully cool off
Performed hard reset on American Standard 1050 thermostat and calibrated touchscreen. Thermostat is now operating properly on both sides of the touchscreen
Upon arrival, my system was completely I stopped loud equipment to deice and dry and verified operation. Found equipment to have faulty circuit board and blower motor will need to call Goodman or John Stone to see availability of circuit board and blower remote.
Upon arrival, found a system calling for cool, but nothing operating thermostat was on only due to battery operated. Verified if 24 V was present at thermostat did not have 24V at thermostat verified voltage at disconnect and made sure breaker was properly set. With further investigation found equipment not being supplied 240 B due to bad fuse at disconnect. Replaced fuse and tested equipment verified volts and amps. Tightened and secured all electrical at contactor and disconnect. System is now cooling and operating properly.
Upon arrival, found system calling for cool but holding indoor unit operating. Upon further inspection found system to have faulty 60/5MFD capacitor as well as compressor not cycling on. Replaced with new 60/5 MFD capacitor and installed compressor saver kit to assist compressor at startup. Equipment is 2006 and past life expectancy but with recommended repairs has now cooling and operating properly. Waived diagnostic fee for member signing up on an annual HFCC.
Today’s annual cooling preventative maintenance consisted of one American standard platinum unit. I first began with replacing the 20 x 30 filter in the home to ensure that proper airflow is able to circulate back to the system at minimal resistance. I then verify that the 1050 thermostat is properly calling for cooling with no error, codes or messages occurring on the system. All of the cooling sequence of operations are successfully checking out verifying there is a proper 20° split between the liquid line and the suction line which verifies that the home is cooling efficiently to the desire temperature. I also cleared the condensation line to ensure that it is properly draining at this time. . The amps of the system are checking out in the correct range verifying a controlled voltage is being used safely following with the system on the mitigation board not having any error codes or messages on there. I then thoroughly wash the coils down of the system to remove all the dirt and deb
Installed recommend repairs
Installed a 4 Ton American Standard Silver 14 SEER Heat Pump Condenser Only.
Arrived to diagnose AC breaker tripping every time the unit starts up. Inspected breaker and outdoor unit and noticed the unit had a minimum amperage of 30.3 and max of 50. The wires to the AC are #8 gauge wires which are good for a 40 amp circuit. I advised the customer to upsize the breaker. When removing the original breaker I noticed overheating on the internal components of the breaker which could be a part of the issue. We installed the new 20/40 quad breaker and had customer turn his AC on. The breaker did not trip. As I was checking the voltage in the disconnect I noticed the condenser making a humming/buzzing noise but did not start up. I had 240 volts on the line and load side of the disconnect as well as the fuses. I believe there is a issue with the condenser.
Diagnostic on 2016 American standard. Loss of 24v electrical circuit. Ohmed out control wires in attic. Located and repaired electrical circuit. Equipment now operating properly. Verified sequence of operation is working properly according to manufacturer specifications.