"As an almost 40-year client of Hydes, my air conditioning/heating systems have been efficiently installed and maintained by three generations of Hydes. Their excellent service and cost-effective recommendations have always been appreciated. The office personnel and on-site service technicians are well-mannered and knowledgeable. I have replaced my air conditioning/heating system several times over the years and have been pleased with the outcome of the installation, the efficiency of the equipment and resulting cost savings. Thank you Hydes management & staff."
See What Customers Are Saying on Google
Recent Jobs and Reviews in Indio, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation. Customers consistently praise the professionalism, knowledge, and friendliness of the service technicians, highlighting their ability to explain technical issues clearly and in understandable terms. A recurring theme is the promptness and efficiency of service, with multiple reviewers noting quick response times, same-day appointments, and rapid problem resolution—particularly impressive given the urgency of air conditioning needs in desert heat conditions. The technicians are frequently described as courteous, personable, and professional, with customers appreciating their thorough work, attention to detail, and lack of aggressive upselling tactics. Many reviews emphasize the company's reliability and punctuality, with technicians arriving on time and completing work efficiently. The positive sentiment extends to the company as a whole, with customers expressing loyalty and trust built over years of service. Overall, the tone is enthusiastic and grateful, with customers feeling well-served by knowledgeable professionals who communicate effectively, work diligently, and provide excellent customer care. The recurring themes of expertise, friendliness, efficiency, and reliability paint a picture of a highly regarded service provider that consistently meets and exceeds customer expectations.
Job Locations and Reviews
System is working fine just thermostat is off line when client is back in town we will reconnect thermostat
Performed annual cooling maintenance on a 2025 American Standard Silver 3ton heat pump. Fau is located in hallway attic access. Cleared condensation line from jones valve. Left 2) 20x30 filters behind for client, stated they’ll change filters. Followed sequence of operations and checked voltage, condenser fan motor amps, compressor start/run amps, capacitor, temperature split, Freon levels, and rinsed condenser coils. Secured all electrical connections. Thermostat checked out operational. System is working properly in cooling at this time of service.
Performed AC Cooling maintenance on 2018 American Standard split system. American Standard 824 thermostat working properly. Cleared condensation drain. Replaced 20x30 and 14x14 ceiling filters. Cleaned out condenser electrical compartment. Rinsed down the condenser coil. Checked all wiring connections are tight and secure. Checked 35/7.5 dual run capacitor within range. Checked compressor and condenser fan motor amps , both within proper range. Checked refrigerant/temperature split (19.9°). System is cooling properly at time of maintenance.
I Performed Maintenance on the Cooling System. Also replaced a 20x30 and 4) 14x14 Filters. The system is a 2026 American Standard Heat Pump 5 ton model located in the master closet attic and outside on the ground. Verified proper refrigerant levels through CDA Display board, verified system amperages, and cleaned condenser coils. Thermostat set at 95 degrees. Client gone for the summer. The system checked out operant within manufactures specifications. Scheduled next maintenance visit online.
Performed annual preventative maintenance on two 2023 American Standard 3-ton heat pump split systems. * Replaced both 16x30 and 14x24 filters. * Verified operation of both Emerson thermostats. Confirmed proper cooling operation and that both systems reached their set temperatures. * Performed a complete operational inspection, including: * Refrigerant pressures * Compressor amperage (running and startup/inrush) * Capacitor testing * Both systems are equipped with 45/5 µF capacitors, and all capacitor readings tested within manufacturer specifications. * Cleaned mini-split filters and indoor coils. * Cleared and flushed the condensate drain lines at both the indoor attic unit and the outdoor termination to verify the primary drain is flowing properly. * Took photos and videos documenting system condition and condensate drainage. * Washed and cleaned both outdoor condenser coils to improve airflow and efficiency. * Confirmed both systems are operating normally at this time.
Performed a cooling maintenance on a 2014 Lennox condenser, condenser located on left of home, filter located in hallway ceiling, fau located in attic, changed 20x30 & 14x14 filter, flushed condensation line, check for thermostat, on condenser check for amperage and voltage, check for compressor, check for freon level, check for capacitors, recommend replacing contractor it was flickering advised HO gave me the okay to replace, check for disconnect box everything within range also clear out dust accumulated inside electrical component area and rinsed condenser coil. System is working within specification in cooling at the time of maintenance.
Performed annual cooling maintenance on a 2011 American Standard 2 ton heat pump. Air handler located in indoor closet. Replaced 18x20 filter located in air handler filter cabinet. Followed sequence of operations and checked voltage, amperage, capacitor, hard start kit, temperature split, Freon levels, cleared condensation line, and rinsed condenser coils. Everything checked out in range. Thermostat checked out operational. System is working at manufacture specifications in cooling at this time of service
Client stated we will wait tell September for installation
Found York Condenser Dual Run Capacitor very low, rated for 70uF Compressor side only reading 10uF. Replaced and tested system. Compressor and condenser fan motor came on and checked temperature split and getting great split over 20°. System is cooling properly now. Ecobee thermostat. 2-systems (Main home and casita). Recommended and signed up for Hyde’s Family Comfort Club Maintenance Plan. Paid by check.
Arrived to diagnose EVC breaker tripping and not charging. I investigated connections on EVC outlet and inside panel. Replaced quad breaker and reconnected wires. Additionally I advised homeowner to check before plugging in home charger that the amperage limit is set to 30 amps max in his Tesla before connecting his charger.